Bosch Rexroth AG
Functions and Parameters
Fig. 12-1: Parameter set selection by b0.12
By digital input:
Parameter set switch will be carried out with an digital input if one of the pa-
rameters E1.00...E1.04 or H8.00...H8.03 is set to option "46: Parameter set
selection". If one of the digital inputs is configured to option 46 it will over-
ride the setting of b0.12 and load the parameter set according to the digital
input during power up. If try to change the value of [b0.12] while digital input
is active, 'S.Err' will be shown.
Fig. 12-2: Parameter set selection by digital input
Terminal value is considered for active parameter set selection only during
STOP mode.
During parameter default loading both parameter sets will be restored to default
values. During parameter set switch from set 1 to set 2, "PAr2" will be displayed
on panel and during switching from set 2 to set 1, "PAr1" will be displayed with
the following restrictions.
1. During parameter backup both sets will be copied and during
restore both sets will be restored.
2. This function is available from firmware version 03V08.