Functions and Parameters
Code
H8.05 EAI input mode
E2.25 AO1 output mode
E2.26 AO1 output setting
H8.26 EAO output selection
H8.25 EAO output mode
C1.73 Motor thermal sensor protection level
Motor thermal model protection time
C1.74
constant
E1.69 Analog input filter time
Activate the function of temperature monitoring with temperature sensor:
Set [E1.60] = '1: AI1 analog input' or
Set [E1.60] = '2: AI2 analog input' or
Set [E1.60] = '3: EAI analog input'
AI1 / AI2 / EAI will be automatically set as voltage input mode when
[E1.60] = 1 or 2 or 3.
Select the sensor type:
[C1.72] = 0: PTC, KTY84/130
For PTC or KTY84/130 sensors, the value of resistor R in the figure should be
close to the sensor resistance when the motor is at high temperature.
[C1.72] = 2: PT100
For a good resolution of temperature with PT100 sensors, the value of resis-
tor R in the figure should be close to the sensor resistance at the motor tem-
perature limit.
[C1.72] = 3: PT1000
For PT1000 sensors, the relationship between the resistor R and the motor
temperature is:
-30 ℃: 882 Ω
0 ℃: 1,000 Ω
220/421
Name
Setting range
0: 0...20 mA
1: 4...20 mA
2: 0...10 V
3: 0...5 V
4: 2...10 V
5: -10...10 V
0: 0...10 V
1: 0...20 mA
11: Motor temperature
sensor power supply
0: 0...10 V
1: 0...20 mA
0.0...10.0 V
0.0...400.0 min
0.000...2.000 s
DOK-RCON03-EFC-X610***-IT06-EN-P
EFC x610 Series
Default
Min.
Attri.
0
Stop
0
Run
0
Run
0
Run
0
Run
2.0
0.1
Stop
DOM
0.1
Stop
0.100
0.001
Run