b) "R-H"
After this button is pressed once, the symbol "R-H" (for Range Hold) appears in the
display (left-hand edge) and the function "Auto Range" (= automatic range changing)
is no longer active. With each further operation of the button, the measuring range is
increased. The change of range can be seen on the one hand from the change of unit
of measurement and on the other hand from the position of the decimal point.
With resistance measurement in the lowest range, the continuity tester (<50 Ohm
acoustic) is activated, indicated by the corresponding symbol in the bottom left cor-
ner. To return to automatic range change, press the "R-H" button longer than approx.
1 s. As a result, the symbol "R-H" disappears from the display.
Note!
This special function is only possible (only selectable) during DC and AC volta-
ge measurement and during resistance measurement.
c) Measuring function switch or rotary switch
The measuring function switch must not on any account be
moved during measurement, as this can damage the measuring
instrument (separation arcing) and as a result the user may be
endangered in the case of voltages greater than 25 VAC rms or 35
VDC.
The measuring function switch must not on any account be set to
voltage measurement (=~V) during current measurement.
Arranged in a semicircle, the various measuring ranges can be selected by turning
the switch clockwise:
=V
=
DC voltage measurement
(Auto Range)
~V
=
AC voltage measurement
(Auto Range)
Ohm ((+)) =
Continuity test and resistance measurement (Auto Range)
->I-
=
Diode test (no auto range)
E.F
=
Electric Field for voltage detection (cable finder)
1.5V
=
Battery test for 1.5 V batteries
=400 mA =
DC current measurement to 400 mA max.
28
Données techniques et tolérances de
mesure
Caractéristiques techniques
Display (affichage)........................: 3 3/4-Display LCD, jusqu'à 3999 avec affichage
automatique de la polarité
Vitesse max. de mesure...............: 1,5 mesures à la seconde
Entrée maximale de courant
électrique AC/DC .........................: 400 mA
Température de fonctionnement..: 0°C à + 40°C (32°F à 104°F)
Température de stockage ............: -10°C à +50°C (14°F 'à 122°F)
Humidité relative de l'air ..............: 0 de 0 à 75 %, sans condensation
Température pour précision
garantie ........................................: +23°C ±5 K
Type de batterie ...........................: 2 x 1,5-V- pile ronde R9, type LR 44 ou SR 44 ou
Renata 357 ou AG13 ou similaires
Poids........................................... : g (avec batterie)
Dimensions (L x l x h)...................: 118 x 73 x 20 mm (sans câbles)
Tolérances de mesure
Précision garantie à ±(% lecture + nombre de positions = digits = dgt(s) )
Précision garantie pendant 1 an à une température de +23°C ±5K, avec une humidité
de l'air relative inférieure à 75 %. Le temps de réchauffement avant usage est de : 1
minute
53