Attention!
Do not measure any currents in circuits in which
voltages greater than 250 VDC or VACrms can oc-
cur, to avoid damaging the measuring device and
endangering life as a result. Never measure cur-
rents over 20 A. Measure only in circuits themselves
fused at 16 A and in which no power greater than
4000 VA can occur.
Measurements of currents at 20 A may be for 30 s
duration max. and be carried out only at intervals of
15 minutes (shunt cooling phase).
D AC current measurement
To measure AC currents, proceed as follows:
1. Connect the black test lead to the COM socket and the red test
lead to the mA socket if currents up to max. 400 mA are to be
measured, or to the 20A socket if currents between 400 mA and
20A max. are to be measured.
2. Position the rotary switch to current measurement (~4mA or
~400 mA or ~20 A ).
3. Connect the test leads in series with the object to be measured
(see following illustration).
fuse
~
current
source
measuring instrument
A
consuming device
(load, circuit, etc.)
Remarques !
L'entrée des mesures étant très sensible, il peut arriver que, si
les câbles de mesure sont libres (c'est-à-dire non reliés à un
objet à mesurer),des valeurs de mesure quelconques soient in-
diquées (valeurs de mesure fantôme). Un tel phénomène est
normal et disparaît dès que vous effectuez des mesures.
B Mesure de tensions alternatives
53
82
Attention !
Ne dépassez jamais les valeurs maximales d'entrée,
même s'il s'agit de mesurer des tensions de cou-
rant continu superposées (par ex. tension de ronfle-
ment) max. 750 VAC rms.
Ne touchez aucun branchement ou corps de bran-
chement, si vous souhaitez mesurer des tensions
supérieures à 25 VACrms ou à 35 VDC.