Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance; High-Pressure Pump; Deliming - Frank FH 711 TCC Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9.

Maintenance

Maintenance and repair services may be carried out by qualified personnel only.
9.1

High-pressure pump

Change the pump lubrication oil at intervals of approx. 200 operating hours, but at the latest,
after 3 months of operation. For lubrication only use branded oils of the SAE 90 quality. To
change the oil, remove the draining screw and drain the oil. Then put the oil draining screw
back into place and refill oil through the funnel until the upper mark on the dipstick is reached.
Properly dispose of the used oil.
Between oil changes, regularly check the oil level; the oil level must always be within the two
marks on the dipstick. If necessary, fill up oil.
9.2

Deliming

If no soft or softened water is used, lime deposits will settle down in the heating coil.
Depending on the local water hardness, the heating coil must be delimed in regular intervals,
to protect the unit from damages.
Do not wait until the pressure is too high and the safety valve responds or the protective mo-
tor switch cuts the machine off. Deliming is carried out as follows.
Set ON/OFF switch to position "0". Loosen joint of the suction hose on the water inlet tank
and connect to deliming hose (which is a ½" hose featuring a filter basket at one end and a
straight hose sleeve with ¾" external thread at the other end) and direct outside. Turn the
knob of the dosing valve to position "0". Fully close the thermostat handwheel.
Fill 16 litres of 50 °C hot water into a container and add 2 litres of deliming compound SP.
Caution! The deliming agent is corrosive. Wear safety clothing. In case of skin con-
tact, rinse with water immediately.
Insert deliming hose into the container, unscrew spray nozzle from the spray lance and place
into the container to allow the deliming solution to flow into the container. The deliming hose
filter must always be situated below the liquid level within the container. Turn on the machine.
The deliming process is complete when the liquid has stopped foaming. Turn off the ma-
chine.
Empty container, properly dispose of the deliming liquid.
Fill 16 litres clear, cold water into the container and add 0.5 litres alcaline cleaning agent.
Reinsert deliming hose and spray lance into the container.
Turn on the machine and flush heating coil using the alcaline solution for 5 minutes.
Turn off the machine, set ON/OFF switch to position (0).
Reconnect suction hose to the water inlet tank, clean and reassemble spray nozzle.
Mount and lock hood.
42

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fh 918 tccFh 1021 tccFh 1024 tccFh 1415 tcc

Inhaltsverzeichnis