Herunterladen Inhalt Inhalt Diese Seite drucken

Working Pressures And Spray Flow Rates; Operating Temperatures; Preparations For Commissioning, Initial Settings - Frank FH 711 TCC Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.3
Working pressures and spray flow rates
Pressure/flow rate regulation
Set desired operating stage on the handwheel of the overflow safety valve when the ma-
chine is switched off and depressurized.
Hot water high pressure stage (HD stage) -
Steam stage (D-stage)
Type
FH 711 TCC
FH 918 TCC
FH 1021 TCC
FH 1024 TCC
FH 1415 TCC
7.4

Operating temperatures

The operating temperature is infinitely variable by means of the thermostat. When using the
high-pressure stage HD, the temperature may only be set to a maximum of 95 °C. For steam
generation (stage D) set the thermostat to 150 °C. During cold water operation the thermo-
stat knob may be turned until the limit is reached.
7.5

Preparations for commissioning, initial settings

Compare the specifications on the machine label to the technical data of this operation
manual. Check oil level of the high-pressure pump.
Works settings:
In our works the machine has been set and tested for the values specified under "4. Tech-
nical Data". The initial settings and tests in our works were performed under the following
conditions:
Room temperature (air temperature)
Mean atmospheric pressure
Extra light oil
Density
Viscosity
Calorific value
-
Operating
Working pressure bar
HD
D
HD
D
HD
D
HD
D
HD
D
: 18 °C
: 986 mbar (740 Torr)
: EL DIN 51603
: 0,842 kg/l at 15 °C
: 4,5 cSt at 20 °C
: 42,7 MJ/kg (10200 kcal/kg)
fully turn handwheel in clockwise direction
fully turn handwheel in anti-clockwise direc-
tion
115
30
180
30
210
30
240
30
150
30
36
Flow rate stage l/min.
11,5
7,3
14,5
7,3
17,0
7,3
17,0
9,5
23,0
9,5

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Fh 918 tccFh 1021 tccFh 1024 tccFh 1415 tcc

Inhaltsverzeichnis