Trouble shooting

Problem
Device does not start
Low or lack of
suction
Float does not
switch the appliance
off
Possible cause
Mains voltage is not
present
Defective on/off switch
(
10)
Worn carbon brushes
Defective motor
Hose system (
jets (
21-24) blocked
Air control on the handle
(
15) open
Collector (
5) open
Collector (
5) full
Filter (
11/12/13) full or
clogged
Float cannot move
Float faulty

Importer

Please note that the following address is
not a service address. Please initially con-
tact the service centre specified above.
Grizzly Gartengeräte
GmbH & CO KG
Am Gewerbepark 2
64823 Groß-Umstadt
Germany
www.grizzly-service.eu

Fault correction

Check plug socket, cable, line,
plug and fuse, where appropriate,
repair through electrical specialist
Repair through customer service
18/19) or
Remove obstructions and blockages
Close the air control
Close collector
Empty collector
Empty, clean or replace filter
Release float
Repair by Customer Care