Herunterladen Inhalt Inhalt Diese Seite drucken

Changing The Oil; Hydraulic Oil - ATIKA ASP 12 TS Originalbetriebsanleitung

Brennholzspalter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 11
When should I change the oil?
The first oil change should be carried out after 50 operating
hours, and then every 500 operating hours.
Two persons are required for this.

Changing the oil:

1. The splitting column must be in run-in state.
2. Now remove the dipstick.
3.
Place a container under the log splitter to catch the old oil.
The container should have a capacity of at least 6 litres.
4.
Screw off the drain plug to allow the oil to flow out.
5.
Insert the seal and drain plug again.
6.
Pour in the new hydraulic oil using a clean funnel.
7.
Clean the dipstick and the oil seal.
8.
Check the oil seal and replace it if it is damaged in any way.
9.
Replace the dipstick.
Dispose of the old oil properly (local oil disposal point). The
old oil must not be poured into the ground or drainage
system, or mixed with other waste.
T
e
c
h
n
i
c
a
l
d
a
t
a
T
e
c
h
n
i
c
a
l
d
a
t
a
Model / Type
Year of construction
Splitting force
Log length
Log diameter
Stroke
Feed speed
Return speed
Hydraulic oil (max.)
Hydraulic pressure
Electric motor performance (power consumption)
Power supply
Dimensions
Weight
26

Hydraulic oil

We recommend the following hydraulic oils for the hydraulic
cylinder:
Shell Tellus T 22
Aral Vitam Gf 22
BP Energol HLP 22
Mobil DTE 11
or equivalent
Do not use any other types of oil. The use of any other type
of oil will adversely affect the operation of the log splitter.
ASP 12 TS
see last page
120 kN (12 t)
max. 1350 mm
min. 80 mm – max. 450 mm
≈ 550 mm
approx. 0.05 m/sek.
approx. 0.22 m/sek.
6 litres
24.5 MPa (245 bar)
P
3.5 kW S6-40%
1
400 V / 3N~+PE 50 Hz, 16 A
length 910 x width 620 x height 1610 mm
approx. 175 kg

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis