Herunterladen Inhalt Inhalt Diese Seite drucken

How To Make Measurements - PeakTech 4350 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 4350:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. How to make measurements

Before making any measurements read safety precautions.
Always examine the instrument and accessories used with the
instrument for damage, contamination (excessive dirt, grease, etc)
and defects. Examine the test leads for cracked or frayed
insulation and make sure the lead plugs fit snugly into the
instrument terminals. If any abnormal conditions exist, do not
attempt to make any measurements.
6.1. Voltage measurements
1. Turn off power to the device under test and discharge all
capacitors.
2. Plug the black test lead into the COM input jack on the meter
and connect the test lead tip to a grounded point (the
reference point for measurement of voltage).
3. Select the voltage measurement position (V
function switch.
4. Select AC or DC voltage by pressing the MODE-button.
WARNING!
To avoid possible electric shock, instrument damage and/or
equipment damage, do not attempt to take any voltage
measurements if the voltage is above 600 V AC/DC are the
maximum voltages that this instrument is designed to measure.
The "COM" terminal potential should not exceed 600 V measured
to ground.
4. Plug the red test lead into the V/-Input jack on the meter and
connect the circuit where a voltage measurement is required.
Voltage is always measured in parallel across a test point.
5. Turn on power the circuit/device to be measured and make
the voltage measurement reduce the range setting if set too
high until a satisfactory reading is obtained.
-32-