5.2

CONTROLLER LAMPS______________________________________________________

The controller is a solid state device that monitors and
controls electrical functions. The controller receives input
signals from various switches and sensors throughout the
machine and transmits output signals to operate relays,
solenoids and warning lights. It controls and resets timers
and contains built in logic to control certain machine
functions.
Each input and output signal is displayed through lamps
located on top of the controller. A closed input switch
indicates an active circuit and will turn an input lamp on. An
open switch an inactive circuit and will turn a lamp off.
Outputs are active when their lights are on.
It is important to note that in some cases a lamp or group of
lamps must be on or off for a condition to be true. For
Lamp On - Circuit is active
Lamp Off - Circuit is inactive
Lamp
1,2,3,4
Program Select (1, 3 and 4 are not used)
5
Brake Switch
6
Seat Switch
7
Traction Control Switch
8
Mow Switch
9
Joystick - Lower
10
Joystick - Raise
11
Hydraulic Oil Level Switch
12
Neutral Switch
13
Not Used
14
Keyswitch - Glowplug
15
Keyswitch - Start
16
Joystick Active
17
Hydraulic Filter Switch
18
Engine Oil Pressure Switch
Controller Functions by Lamp Number
INPUTS
Circuit
INPUTS
TROUBLESHOOTING
example, to start the mower the Mow Switch must be off
(lamp 8 off) while the Neutral Start Switch (lamp 12), Brake
Switch (lamp 6) and Fuel Valve Hold Coil (lamp 27) must be
on.
NOTICE
For factory assistance with troubleshooting controller
problems, please note the controller hardware revision
and software version located on the lower right corner of
the controller. [SEE Parts & Maintenance Manual]
Controllers with equal or greater revision levels will be
backward compatible.
OUTPUTS
Lamp
19
Hydraulic Filter Light
20
Hydraulic Oil Level Light
21
Not Used
22
Glowplug Light
23
Lower Solenoid
24
Raise Solenoid
25
Glowplug Relay
26
Start Relay
27
Fuel Solenoid - Hold
28
Not Used
29
Audible Alarm
30
Mow Solenoid
31
Fuel Solenoid - Pull
32
Power-Ignition
33
Power-Lights
OUTPUTS