Herunterladen Inhalt Inhalt Diese Seite drucken

Functional Description; General Points - SATA SATAjet 1000 B HVLP Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SATAjet 1000 B HVLP:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Operating instructions SATAjet 1000 B (RP/HVLP)

2. Functional Description

2.1 General Points

The SATAjet 1000 B RP/HVLP paint spray gun is designed for spraying paints and laquers as well
as other media (Nozzle size depends on spray viscosity). Materials that are abrasive, acidic or contain
benzine must not be used. The compressed air supply required for spraying is fed to the air connec-
tion screwed into the gun grip. Squeezing the trigger as far as the first pressure point opens the air
valve (pre-air control). When the trigger is squeezed further, the paint needle is pulled out of the paint
nozzle. The spraying medium then flows unpressurized out of the paint nozzle due to gravity and is
simultaneously atomized by the compressed air that flows the air nozzle.
The cup lid is equipped with a drip stop that prevents the material from escaping from the vent hole.
2.2 Digital Pressure Measurement (add-on solution)
From 0.2 bar (3 psi) on, the digital pressure measuring device integrated in the „SATA adam" indicates
the gun inlet pressure with an indication precision of ± 0.05 bar (1 psi). If unpressurized, the pressure
measurement is put into „sleep" mode to prolong battery life time. The pressure measuring device
is hermetically sealed against external influence (max. temperature 60° C). The maximum indication
value is 99 psi or 9.9 bars.
2.3 ATEX, FM Global (Explosion hazard safety)
The digital pressure measurement device „adam" has been submitted to a prototype test and was
developed, constructed and manufactured in accordance with the EC Directive 94/9 EG.
It was categorized according to
and may be used in the explosion hazard zones 0, 1 and 2 with a temperature of up to 60° C. In
case of damage to the pressure measuring device, indication, glass cover etc. put gun out of order
immediately. The pressure measurement device may exclusively be repaired in the SATA company.
Any intrusion into the pressure measuring chamber by removing the front plate is dangerous,
will lead to the expiry of the explosion hazard safety certificate as well as the warranty, and
destroys the pressure measurement device.
3. Construction
1
Nozzle set (air cap visible only)
2
Self tensioning needle packing (not visible)
3
Trigger
4
Self tensioning air piston packing
(not visible)
5
Stepless regulation for round and flat spray
6
ColorCodeSystem
VIII.2
II 1G EEx ia IIC T4
FM Global IS CL I, ZN 0, AEx ia IIC T4
IS CL I, DIV 1, GP A, B,C&D, T4
7
Air connection G ¼ outside
8
Air piston (not visible)
9
Fixing screw
10 Air micrometer
11 Fluid adjustment
12 Material sieve (not visible)
13 Non-drip device (not visible)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis