6.2 Setting ventilation levels
In automatic mode, the ventilation unit runs
at the ventilation level programmed for the
corresponding time in the week program
(→ Chapter 6.6), or according to the humidity
sensor.
Turn
to the right until "Manual" is
displayed and the bar count or arrow
direction displays the required ventilation
level.
Turn
to the left until "Auto" is displayed
to switch into automatic mode.
The manually set ventilation level runs
i
until you rest it to automatic mode.
Sequence of the ventilation levels
Automatic mode and manual mode
Function
Ventilation
level
Off*
Ventilation unit off
Level 1
Operation with heat
1 bar
recovery, 17 m³/h.
Level 2
Operation with heat
2 bar
recovery, 30 m³/h.
Level 3
Operation with heat
3 bar
recovery, 45 m³/h.
Level 4
Operation with heat
4 bar
recovery, 60 m³/h.
Only supply air
Operation with ventilation
arrow inwards
level 1, 2, 3 or 4. Factory
setting level 2 / 30 m³/h.
Without heat recovery.
Exhaust air fan off.
Exhaust air shutter closed.
Only exhaust air
Operation with ventilation
arrow outwards
level 1, 2, 3 or 4. Factory
setting level 2 / 30 m³/h.
Without heat recovery.
Supply air fan off.
Supply air shutter closed.
*
The off function can also be completely
deactivated so that the ventilation unit
runs permanently and also cannot be
switched off by persons who are not
authorised to do so (→ Service menu).
6.3 Program structure, Menus
Main menu
The starting image appears on the graphical
display.
Press
.
Press
until the required Main menu
item appears.
Press
.
Main menu
Activate Party operation.
Activate Standby operation
Week timer:
● Standard week program
● Individual week program
Vacation program
Sensor values: Only for
WRG 35H to query the
relative humidity values (r. h.).
Otherwise, no function.
Settings (→ Menu)
Exit
GB
→ Chapter 6.4
→ Chapter 6.5
→ Chapter 6.6
→ Chapter 6.7
→ Chapter 6.8
→ Chapter 6.9
43