6.7 Vacation program

Here you can set a special ventilation
program for vacation times.
The vacation program starts automatically on
the date entered as the start of the vacation.
At the end of the vacation, the controller
automatically switches back to the standard
week program or to manual operation.
Interval or permanent operation can be
defined with a required ventilation level.
In the case of interval operation, the interval
time and the switch-on time per interval
can be defined (interval time = switch-on
time + switch-off time). There is a continuous
series of changes between the on and off
phases.
Required settings
You get to the Vacation program menu item
from the Main menu.
 Here you enter the following
parameters, one after the other:
● Vacation program to "ON"
(factory setting is OFF)
● Start of vacation "DD.MM.YYYY"
● End of vacation "DD.MM.YYYY"
● Interval to "ON" or "OFF"
(factory setting is OFF)
ON = Interval operation with defined
interval time, switch-on time per interval
and ventilation level.
OFF = Permanent operation with defined
ventilation level.
● Interval time 1 to 24 h (factory setting, 1 h).
● Switch-on time per interval, 5 to 180 min.
(factory setting, 5 min). The ventilation unit
is switched off for the remaining period of
the interval.
● Level: The ventilation level assigned to
the vacation program. Ventilation levels 1,
2, 3, 4 supply air or exhaust air operation
are available (factory setting, ventilation
level 1).
If the vacation program is active, the text
"Vacation until end date" appears.
 Press
Deactivate, if you want to switch
off this function ahead of time.

6.8 Sensor values

The currently recorded environment
parameters can be queried through this sub-
menu.
You get to the Sensor values menu item from
the Main menu.
 Select the required environment parameter
with
.
● Temperatures: No function, no display
values.
● Relative humidity in % r.h. (only with
WRG 35H-SE). Measurement at the
humidity sensor in the ventilation unit.
No display values with the standard
WRG 35-1-SE device.
Co2
sensor: No function, no display
values.
In master/slave networks, the
i
humidity value of the master device
is always displayed at the RLS 5.
Recommendation: Always install the
WRG 35H as the master device.

6.9 Settings menu

You get to the "Settings" menu from the Main
menu.
 Confirm with
 Select the required menu item with
 Press
to get to the menu item.
.
GB
.
47