11.2 Switch-on, function test with
RLS 5
 During initial commissioning, set the device
address, language and date & time at each
room air control.
● Device address for devices 1 to 4
● Language, German or English
● Date and time
The setup parameters are requested
automatically. For detailed information, refer
to Settings menu and Service menu in
Chapter 6.9 and 6.10.
Then, the starting image appears on the gra-
phical display of the RLS 5, as per Chapter 6.1.

12. Accessories

Accessory / Product type
WRG 35-G4 Replacement air
filter: Filter class G4, 2 pieces
Only for supply air: WRG 35-F7
Replacement air filter: Filter
class F7 (Pollen filter)
RLS 4-1 AP Room air control,
incl. control cable, 5 m
RLS 4-1 UP Room air control,
incl. control cable, 5 m
RLS 5 AP Room air control,
incl. control cable, 5 m
RLS 5 UP Room air control,
incl. control cable, 5 m
Extension sleeve WRG 35-VH:
111.5 mm, including 2 separa-
ting bridges and condensation
run-off extension hose
Compensating frame
WRG 35-VH: For compensating
for wall thicknesses < 350 mm
WRG 35-AAD Junction box.
WRG 35-TAK 5 Control cable
(5 m long)
WRG 35-TAK 10 Control cable
(10 m long)

13. Technical data

Wall sleeve
measurements
Protection class
Degree of protection
Supply air filter / Exhaust air
filter
Optional supply air filter
Permitted ambient
temperature
Heat recovery coefficient
Rated voltage
Power frequency
Nominal current
Article no.
Ventilation level 1
0192.0452
Ventilation level 2
Ventilation level 3
Ventilation level 4
0192.0453
Power consumption, free
outlet, at:
17 m³/h
0157.0847
30 m³/h
45 m³/h
60 m³/h
0157.0848
Sound pressure level at
3 m distance, at:
0157.0845
17 m³/h
30 m³/h
45 m³/h
0157.0846
60 m³/h
Sound insulation D
0192.0451
Weight, both sets:
Shell set
Final assembly set
0192.0454
0092.0501
0092.0502
0092.0503
346 mm x
External dia-
meter 350 mm
II
IP X4
Air filter,
Filter class G4
Pollen filter,
Filter class F7
-20 ... +40 °C
> 70 %
230 V AC
50 Hz
0.07 A
17 m³/h
30 m³/h
45 m³/h
60 m³/h
2 W
4 W
6 W
8 W
18 dB (A)
22 dB (A)
29 dB (A)
30 dB (A)
39 dB(A)
NE
Approx. 9 kg
3.25 kg
5.55 kg
GB