The battery is connected but
the charger does not work
correctly (possibly the LED's
also show incorrect
behaviour)
Power LED lights red*.
*
= when the 'power' LED lights red, it is possible to request the concerning error by
means of pushing the 'power/mode' button shortly. With the 4 LED's from 'setting'
can be read which error is ascertained (LEDs are flashing). See overview on page
34. Advise also the explanations of the concerning section of the chapter 'Features'.
Charger is set on the power
supply mode.
Battery connection problem:
- No battery present
- Bad connection between
battery and charger
- Reverse polarity
- Short circuit
Charger is in a thermal stop.
AC input too low.
The bulk stage takes longer
than 14 hours.
Hardware/software problem.
Warning for a too low battery
voltage.
Battery voltage too high.
Charge process stopped.
Change the setting, see chapter
'Setting the charger'.
Check the connection to the
battery on faults.
The charging process will
continue automatically when the
charger has cooled down.
Check the mains voltage. It
should be higher than 180VAC.
The battery is damaged/
broken. Check the battery.
Heavy users present during
charge process. Shut down as
many users as possible.
The charger has insufficient
current for the concerning
battery capacity.
Send the charger back to
supplier/manufacturer.
Indication will light for 3 min.
The charge process will start as
usual.
Check if the system voltage is
the same as the output voltage
of the charger