and the glass ceramic, high temperature resistant front screen of the VISION heaters
provide best protection of the installed carbon heating elements.
Functional description of the NTC temperature control: If the system temperature
of the electronical control exceeds 103°C, the upper heating element will shut off
temporary by default to avoid over heating of the electronical parts. After a short
time the heating element will switch on automatically again. The self-controlled
shut off of the heater will take place only, if the heat dissipation inside the device is
inappropriate, if the heat radiation is interfered or if the ambience temperetaure is
way too high. Apart from that the NTC temperature control supports energy safings,
if the ambient temperatures are too high and the highest heating level of the heating
unit is not necessary.
Functional description of the latching temperature limiter: If the NTC temperature
control is not working against expectations, the latching temperature limiter will shut
down the lower heating element permanently (two red lights are flashing on the
front of the device), until the heater is shut off totally by hand. After cooling down
(warm to the touch) and fixing the inappropriate heat dissipation inside the device
and/or the interferred heat radiation the heater can be switched on again (the two
red light on the front stopped flashing). If the lower heating element shuts down
once more (or if the two red lights continue flashing), a system malfunction or a heat
dissipation inside the device or an interference of the heat radiation or an error in
the electrical installation may be the reason. If a system malfunction inside the de-
vice causes the shut down, the heater must be repaired by a professional technician;
please contact your dealer immediately. If a wrong cable connection causes the shut
down, this has to be checked and fixed through a professional electrician on the spot.
Installation and connecting regulations with tested and approved luster terminals are
part of the delivered equipment.
13. The radiant heater must not be installed directly below a power source/socket.
The sides of the unit must be at least 20 cm from the nearest power source. Sockets/
power sources must be freely accessible at all times and comply with the following
specifications: 220–240 V AC ~, 50/60 Hz, 16 A with 16 A fuse. No other loads may be
connected to this power source.
14. The radiant heater must not be installed in rooms where there is high humidi-
ty (bathroom, spa, pool etc.) in close vicinity to bathtubes, showers or pools. The
distance to the bathtub or shower must be at least 100 cm and the distance to the
pool at least 200 cm. A person standing in the bathtube, shower or pool should never
reach the switch or controller of the heater. If the HEATSCOPE® is installed in such