  • Seite 1 ORIGINAL MONTAGE- UND GEBRAUCHSANLEITUNG Elektrischer Strahlungsheizer für äußerst geschützte Innen- und Außenbereiche ORIGINAL INSTALLATION AND INSTRUCTION MANUAL Electric radiant heater for well covered/protected indoor and outdoor areas Made in Germany Downloaded from www.Manualslib.com manuals search engine...
  • Seite 2: Verwendung & Abmessungen

    1. Verwendung & Abmessungen Vielen Dank, dass Sie sich für den Kauf des elektrischen Heizstrahlers HEATSCOPE® ZERO entschieden haben. Der sog. Dunkelheizstrahler auf Infrarotbasis zeichnet sich durch eine fokussierte Wärmeverteilung aus, die die Wärme dorthin transportiert, wo sie benötigt wird.
  • Seite 3: Sicherheitshinweise

    6. Nach VDE 0100, Teil 701 darf der Heizstrahler nur im Bereich 3 in Installationsräumen mit hoher Feuchtigkeit (Bad, Spa, Pool etc.) montiert werden. Wenn der HEATSCOPE® ZERO in einem solchen Umfeld mit hoher Feuchtigkeit montiert wird, müssen die Schalter oder anderen Bediengeräte so angebracht werden, dass sie nicht von Personen, die sich im direkten Kontakt mit Wasser befinden, berührt werden können.
  • Seite 4 Natriumhydroxid oder Seife. Es dürfen nur Reiniger mit Tensiden und schwachen Lösungsmitteln wie Alkohol verwendent werden. 4. Montageanweisungen In den Abbildungen am Ende der Anleitung werden die EINZELNEN Montage möglichkeiten des HEATSCOPE® ZERO ab gebildet. Achten Sie darauf, dass der Heizstrahler sicher und fest mit der Montageoberfläche verbunden ist. Die Befesti- gungselemente müssen eine Zug­...
  • Seite 5: Betrieb

    Nach erfolgreicher Installation / Montage können Sie das Gerät in Betrieb nehmen. Der HEATSCOPE® ZERO besitzt eine LED, die in der Abdeckplatte zwischen Heizprofil und Oberschale integriert ist. Sobald der HEATSCOPE® ZERO mit Strom versorgt wird, leuchtet diese LED auf und signalisiert, dass das Gerät sich im Betriebsmodus befindet.
  • Seite 6: Mindestabstände Auf Brennbaren Materialien/Untergründen

    Letztere sind in jedem Fall einzuhalten. Die dargestellten Montageflächen müssen mindestens der Brand schutzklasse A2 entsprechen. Bitte beachten Sie: Der HEATSCOPE® ZERO erfüllt bei der Deckenmontage die IP­Schutzklasse 4 (IP­X4), bei der Wandmontage die IP­Schutzklasse 0 (IP­X0). Vorgeschriebene Abstände zu brennbaren Montageflächen: mind.
  • Seite 7: Reinigung Und Wartung

    8. Reinigung und Wartung Es ist wichtig, dass der HEATSCOPE® ZERO, sofern er im geschützten Außenbereich angebracht wird, regel mäßig ge reinigt wird, um eine möglichst langlebige und effiziente Funktionsweise zu gewährleisten. Die Aluminiumbauweise des HEATSCOPE® ZERO in Verbindung mit der eloxierten Oberfläche schützt den Heiz- strahler auch in Küstennähe.
  • Seite 8: Konformitätserklärung

    Die Konformitätserklärung erhalten Sie auf Wunsch gerne direkt bei uns. Kontakt siehe Rückseite. 11. Garantie & Gewährleistung Der HEATSCOPE® ZERO hat eine Garantie von 24 Monaten. Die Garantiezeit beginnt am Tag, an dem das Neu­Gerät erworben wurde. Verschleißartikel oder Mängel, die die Gebrauchstauglichkeit des Gerätes nur uner- heblich beeinflussen, sind von der Garantie ausgeschlossen.
  • Seite 9: Außerbetriebnahme / Entsorgung

    MHS-ESM MHS-ASK* * Der HEATSCOPE® ZERO Heizstrahler wird regulär mit offenem Kabel ohne Stecker ausgeliefert. Der Anschluss und die entsprechenden notwendigen Prüfungen für ortsfeste Geräte müssen von einer Elek trofachkraft durch- geführt und dokumentiert werden. Beachten Sie die jeweils gültigen Normen.
  • Seite 10: Technische Daten

    16. Technische Daten Betriebsspannung 220­240 V / 50 Hz Temperatur bis zu 380° C (MHS­ZE1800, MHS­ZE2400, MHS­ZES3200) Heizfläche bis zu 310° C (MHS­ZE600) Temperatur bis zu 90° C Gehäuse Aufheizzeit ca. 15 min. Schutzklasse bei der Deckenmontage IP­X4 bei der Wandmontage IP­X0 Betriebs umgebungs- ­5°C bis +23°C temperaturen...
  • Seite 11 Bitte beachten Sie: Alle Angaben in dieser Anleitung entsprechen dem heutigen Stand unserer Kenntnisse und sollen über unsere Produkte und mögliche Anwendungen informieren (technische Änderungen und Weiter entwicklungen, Irrtü- mer und Druckfehler vorbehalten). Diese Montage - und Bedienungsanleitung umfasst folgende Produkte: MHS­ZE600BK.300 MHS­ZE1800BK.300 MHS­ZE2400BK.300...
  • Seite 12 1. Usage & Measurements Thank you for choosing to purchase the electric radiant heater HEATSCOPE® ZERO. You have purchased one of the most advanced heating systems for indoor and covered outdoor areas. The infrared radiant heater without red light is characterized by a focused distribution of heat, which transports the heat to where it is needed.
  • Seite 13: Safety Instructions

    1. The HEATSCOPE® ZERO must be fitted with an all­pole ON/OFF switch (not included in scope of delivery). You can likewise operate the radiant heater using a radio receiver and a remote control, which are available as optional accessories.
  • Seite 14: Installation Instructions

    Natriumhydroxyd or soap. Just use cleaner with tensides and low solvents like low alcohol etc. 4. Installation instructions The different options for installing the HEATSCOPE® ZERO are shown in the diagrams at the end of this manual. Make sure that the radiant heater is securely connected and fixed to the installation surface. The fasteners must be of a tensile and shear strength of at least 3 times the weight of the radiant hea- ter that is being mounted including the accessories.
  • Seite 15: Operation

    Note here in any case the operating instructions supplied with each accessory. Although there is power to the HEATSCOPE® ZERO, it is possible that the LED likewise does not light if the temperature protection was activated. Do not forget to switch off your HEATSCOPE® ZERO again! 6.
  • Seite 16: Minimum Clearances

    These must be observed and complied with in any case. The illustrated installation surfaces must comply at least with fire protection class A2. Please note: The HEATSCOPE® ZERO fulfills IP protection class 4 (IP­X4) for ceiling mounting and IP protection class 0 (IP­X0) for wall mounting.
  • Seite 17: Cleaning And Maintenance

    8. Cleaning and maintenance It is important that the HEATSCOPE® ZERO is cleaned regularly when installed in outdoor locations, in order to ensure a long and efficient operating life. The aluminum construction of the HEATSCOPE® ZERO together with the anodized surface helps to preserve the heater even in coastal locations.
  • Seite 18: Conformity Declaration

    A conformity declaration is available upon request directly from us. Contact information at the back. 12. Guarantee and warranty The HEATSCOPE® ZERO is guaranteed for 24 months. The warranty period begins on the date on which the new unit is purchased. Consumables or defects that affect the usability of the unit only slightly are excluded from the warranty.
  • Seite 19: Replacement Parts

    MHS-ASK* MHS-ESM * The HEATSCOPE® ZERO ¤ radiant heater is normally delivered with an open cable without a plug. The connection and the relevant tests required for stationary units must be performed and docu- mented by a qualified electrician. Note here, in any case, the appropriate standards, e.g. VDE etc.
  • Seite 20: Technical Data

    15. Technical Data Operating voltage 220­240V / 50 Hz Temperature of Up to 700°F / 380°C (MHS­ZE1800, MHS­ZE2400, MHS­ZES3200) heating surface Temperature of Up to 194°F / 90°C housing Heat up time approx. 15 min. Protection class IP X4 for ceiling­mounted IP­X0 for wall­mounted Operating ambient 23°F to +73,4°F / ­5°C to + 23°C...
  • Seite 21 Please note: All information in this document reflects our current state of knowledge and is intended to inform customers about our products and possible applications for them (technical changes and improvements, errors and prin- ting errors excepted). This manual includes the following items: MHS­ZE600BK.300 MHS­ZE1800BK.300 MHS­ZE2400BK.300...
  • Seite 22 MHS-MH (Deckenmontage / Ceiling mounting) (Befestigungsschrauben für Deckenmontage nicht im Lieferumfang enthalten) (screws for ceiling mounting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 23 MHS-WH45 (Befestigungsschrauben für Decken­/Wandmontage nicht im Lieferumfang enthalten) (screws for ceiling / wall mounting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 24 MHS-WHSL Versionstabelle Index Version Änderung Datum Name Bezeichnung Wandhalterung verstellbar Werkstoff Baugruppe Firma MHS GmbH Ludwig Michl GmbH Material/mm Zeichn.-Nr. 437591 Oberfläche Index/Stand -- / -- B / 23.10.2013 / 0 Gewicht/kg 0.55 Maßstab 1:2 Ludwig Michl GmbH 3D-Modell J. Aigner Brunnenweg 40 Fläche/m²...
  • Seite 25 MHS-DAH + MHS-DAHDB (Deckenmontage / Ceiling mounting) (Befestigungsschrauben für Deckenmontage nicht im Lieferumfang enthalten) (screws for ceiling mounting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 26 MHS-DAH + MHS-DAHV + MHS-DAHDB (Deckenmontage / Ceiling mounting) (Befestigungsschrauben für Deckenmontage nicht im Lieferumfang enthalten) (screws for ceiling moun- ting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 27 MHS-DAHGMS + MHS-DAHDB Befestigungsschrauben für Decken­/Wand- montage nicht im Lieferumfang enthalten) (screws for ceiling / wall mounting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 28 MHS-DAHDOP + MHSDAH + MHSDAHDB (Deckenmontage / Ceiling mounting) (Befestigungsschrauben für Deckenmontage nicht im Lieferumfang enthalten) (screws for ceiling mounting not included in the delivery) Downloaded from www.Manualslib.com manuals search engine...
  • Seite 29 Downloaded from www.Manualslib.com manuals search engine...
  • Seite 30 Element MHS­ESM bzw. für die Installation des HEATSCOPE® ZERO auf brennbaren Materialien ist die Verlängerung MHS- DAHS4 obligatorisch.) (mandatory for installation of a HEATSCOPE® ZERO with a connecting element MHS-FBM or MHS-ESM and for installa- tion of a HEATSCOPE® ZERO on combustible surfaces) Downloaded from www.Manualslib.com...
  • Seite 31 Downloaded from www.Manualslib.com manuals search engine...
  • Seite 32 FRANCE TURKEY SPAIN SARL HEATSCOPE FRANCE Uluslararasi Girisim Grubu Home Garden & Lifestyle Solutions S.L. ZI Les gresses Adnan Saygun Cad. Lale Sok. 5/1 Av. Autopista del Saler 6­43 26290 Donzère FRANCE TR­34340 Ulus ­ Istanbul ES­46013 Valencia...

Diese Anleitung auch für:

Mhs-ze1800Mhs-ze2400Mhs-ze3200

Inhaltsverzeichnis