Herunterladen Diese Seite drucken

Victron energy Phoenix Multi 12/2000/100 Installationsanleitung Seite 8

Vorschau ausblenden Andere Handbücher für Phoenix Multi 12/2000/100:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2. SETTINGS
Settings may only be changed by a qualified engineer
Carefully read the instructions before changes are made.
When setting the charger, all connections to the battery must be
disconnected from the Phoenix Multi or MultiPlus.
Do not use non-rechargeable batteries.
The Phoenix Multi/ MultiPlus default settings are for charging
Sonnenschein Dryfit A200 gel batteries. For the recommended battery
voltage see section 2.4.
Batteries should be placed in a dry and well-ventilated area during
charging.
2.1 Settings – General
2.1.1 Push buttons and dipswitches
A selected number of settings may be changed with the aid of pushbuttons and dip switches
(see Appendix A).
Dipswitches are used to activate set-up, and to determine the setting to be changed. The
value of this setting can be changed with the aid of the pushbuttons.
The value specified is shown on the LEDs. Sections 2.3 describes how the LEDs can be
read.
2.1.2 VEConfigure software
All settings can be changed with VEConfigure.
VEConfigure can be downloaded from www.victronenergy.com
2.2 Default Settings
System frequency
Inverter Voltage
Charger on/ off
Charger characteristic
Charging Current
Battery Type Presets
Absorption Voltage
Absorption Time/ Maximum Absorption Time
Float Voltage
Repeated Absorption Time
Repeated Absorption Interval
Bulk Protection
AC Waveform Check
Generator/ Shore Current
PowerAssist (MultiPlus only)
3-phase Setting
Master/ slave
(To restore the default settings, both pushbuttons should be held down for 3 seconds while
set-up is activated)
6
50 Hz
230 Vac
on
Adaptive with BatterySafe mode
75% of maximum charging current
type 1 (Exide Gel battery)
14.4/ 28.8/ 57.6 Vdc
4 hours
13.8/ 27.6/ 55.2 Vdc
1 hour
7 days
on
on
16 A (optional: 30 A)
on
off
slave

Werbung

loading