Checking The Direction Of Rotation Of The Motor And Adjustment Of The Motor End Limits; Installing An Optical Radio Safety Edge Or Resistive Safety Edge With Xse Transmitter; Installing The Optical Radio Or Resistive Safety Edge And Its Xse Transmitter; Installing A Base Magnet On The Door Runner - SOMFY ROLLIXO io Installationsanleitung

Vorschau ausblenden Andere Handbücher für ROLLIXO io:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Rollixo io
3.4 Checking the direction of rotation of the motor and
adjustment of the motor end limits
[1]. Press simultaneously on the
down movement occurs to enter motor adjustment mode.
Indicator light 1
1
2
3
STOP
[2]. Press button
or
to check the motor's direction of rotation.
- If the motor's direction of rotation is correct, move on to step [3] of the
motor end limit setting procedure.
- If the direction of rotation is incorrect, press button
up and down movement occurs, check the motor's direction of rotation
again and move on to step [3] of the motor end limit setting procedure.
1
2
3
4
STOP
Correct direction of
Incorrect direction
rotation
of rotation
Step [3]
[3]. If the motor end limits are already set, move on to step [8] to exit motor
adjustment mode.
If the motor end limits are not set, check that the motor is released: the
two push-buttons should be pressed.
Note: The motor end limits can also be set with a setting cable (ref.
9015971). In this case, set the motor end limits with the cable then
move on to step [8] to exit motor adjustment mode.
[4]. Press button
to position the garage door in the upper position.
Adjust the top position using buttons
1
2
3
4
STOP
Prog
6
and
buttons until the motor's up and
4
Prog
until the motor's
STOP
Prog
1
2
3
4
STOP
Prog
and .
[5]. Press the motor's upper end limit push-button.
or
[6]. Press button
to position the garage door in the low position.
Adjust the bottom position using buttons
1
2
3
4
STOP
Prog
[7]. Press the motor's low end limit push-button.
or
[8]. Press simultaneously on the
until the motor's up and down movement occurs to exit motor adjustment
mode.
Indicator light 1
goes out.
1
2
3
4
STOP
Prog
or
1
2
3
4
STOP
Prog
4 - INSTALLING AN OPTICAL RADIO
SAFETY EDGE OR RESISTIVE SAFETY
EDGE WITH XSE TRANSMITTER
4.1 Installing the optical radio or resistive safety edge
and its XSE transmitter
Follow the instructions provided with the XSE transmitter and the optical or
resistive safety edge installation kit.

4.2 Installing a base magnet on the door runner

Lower
magnet
and .
and
buttons or press the
button
Prog
for a resistive safety edge.
This is recommended for an
optical safety edge in order to:
- extend the battery life
- eliminate the risk of ground
detection,
to
secure
closing of the door
- automatically
activate
maximum level of sensitivity of
the movement sensor
- increase the sensor operating
time by 25 to 35 seconds when
the base magnet is detected.