Herunterladen Inhalt Inhalt Diese Seite drucken

User Training; Connecting Additional Devices; General Wiring Diagram; Description Of The Various Additional Devices - SOMFY ROLLIXO io Installationsanleitung

Vorschau ausblenden Andere Handbücher für ROLLIXO io:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Rollixo io

6 - USER TRAINING

Train all uses in how to safely use this motorised door (standard use and
locking principle) and on the mandatory periodic checks.

7 - CONNECTING ADDITIONAL DEVICES

7.1 General wiring diagram

Stop
Safety Edge
M
Sec
L1
N
L2
1
2
3
4
5
6
7
8
R
Terminal Type of
Connection
terminal
1
Earth
RDO CSI 50 or 60
motor
2
L1
3
Neutral
4
L2
5
Contact
Fall protection - NC
contact
6
Shared
7
Contact
Safety edge safety
input
8
12 Vdc
12 Vdc safety edge
power supply
9
0 Vdc
10
Contact
NO contact
11
Shared
12
24 Vdc
24V - 3.5 W orange
light output
13
0 Vdc
14
24 Vdc
TX cell 24 V power
supply
15
0 Vdc
16
24 Vdc
RX cell 24 V power
supply
17
0 Vdc
18
Shared
19
Contact
Cell safety input (NC)
20
Test output
Cell safety test output
22
433.42 MHz aerial
8
KeySwitch
Flash
24V dc
24V Cell
Sec Cell
Test
Sec
9
10
11
12
13
14
15
16
17
18
19
20
24 Vdc
24 Vdc
Aerial
Comments
Wired 8k2 resistive safety
edge (terminals 7 - 8)
Wired optical safety edge
(terminals 7 - 8 - 9)
Sequential control
Maximum 4 W bulb
Transmitting photoelectric
power supply
Receiving photoelectric
cell power supply
Do not connect an offset
aerial (incompatible)
7.2 Parameter setting for wiring options
Possible parameter
Dipswitch
setting
1
Cell self-test
2
Choice of cell type
3
Orange light 2s
warning
4
Choice of wired safety
edge type
5
Holiday mode parameter setting (see section 8.4)
6
Do not use
Ant
22
Antenne
STOP

7.3 Description of the various additional devices

> Photoelectric cells
N.B.: In accordance with standard EN 12453 governing the safe use
of motorised gates and doors, the use of the TAHOMA control box to
automatically control a garage door or gate not visible to the user requires
the installation of a photoelectric cell type safety device with autotest on the
automatic control system.
Receiver
Dipswitch 1 Dipswitch 2
Without auto-
OFF
test
With auto-test
ON
It is compulsory to install photoelectric cells if:
- the automatic control device is being controlled remotely (user unable to see it),
- automatic closure is activated.
If cells are removed, it is essential to create a bridge between
terminals 18 and 19.
ON
Activated
Photoelectric
Activated
Resistive
1
2
3
4
Prog
WARNING
Comments
ON
Requires checking for
correct operation every 6
months.
ON
Enables an automatic
test to be carried out to
check the operation of the
photoelectric cells each time
the door moves.
If the operational test is
negative, closure is in
downgraded mode (press
and hold down
WARNING
Copyright © 2014 Somfy SAS. All rights reserved.
OFF
Deactivated
Electric eye
Deactivated
Optical
).

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis