Abgleich / Alignment
Alignment
1. Tuner
Test Equipment:
Sweep generator, Test generator, Stereo coder, AF generator, Oscilloscope, Digital voltmeter, AF voltmeter, Distortion meter
Note:
The frontend is a completely preadjusted module. Only the IF filter must be adjusted to the IF amplifier (1). The values of the tuning voltages are:
87.5MHz = typ. 1.6V min 1.3V
108MHz = typ. 8.0V max 9V
Adjustment
1. IF Filter
FM, 98MHz.
Sweep generator 98MHz to aerial socket. Level approx.
100µV / 75Ω.
Oscilloscope to testpoint B .
2. Demodulator
FM, 98MHz
Test generator 98MHz to aerial socket. Level approx.
100µV / 75Ω, ∆f = ± 40kHz.
Distortion meter to AF output
3. Station search
FM, 98MHz.
Test generator 98MHz, V
Digitalvoltmeter to testpoint G .
4. Stereo Crosstalk
FM
Stereocoder, left channel modulated, to aerial socket.
AF voltmeter to AF output, right channel
5. Adjacent channel
FM
AF generator 114kHz, approx. 100mV to the input of F2 D
filter
(Pin 2).
AF voltmeter to the output of F2 D
6. 38 kHz Filter
FM
Test generator to aerial socket; FM, f
AF voltmeter to AF output
7. 19 kHz Filter
Test generator to aerial socket; FM, f
AF voltmeter to AF output
MW, 531kHz
8. MW Oscillator
Digitalvoltmeter to testpoint E .
9. MW RF Circuits
MW, 1449kHz / 558kHz
Test generator via 120 -150µH parallel to frame aerial; AM,
V
= 3µV, m = 30%, f
RF
AF voltmeter to AF output
2 - 6
Preparations
L
R
.
= 100µV / 75Ω to aerial socket.
RF
.
R
D
D
D (Pin 4).
D
= 38kHz.
mod
.
L
R
= 19kHz.
mod
.
L
R
= 1kHz.
mod
.
L
R
Adjustment Procedure
Adjust F1 a to maximum and symmetry.
Adjust F7 i to K
(typ. 0.12%, max. 0.2%).
min
Adjust R123 S to 1.2V + 0.05V.
Adjust R69 C to minimum.
Control the left AF output with modulated right channel.
Adjust F2 D to minimum.
Adjust F9 J (left channel) and F11 K (right channel) to
minimum.
Adjust F9 G (left channel) and F11 H (right channel) to
minimum.
Adjust L18
to 1.1V.
VI
Adjust C3
and IF filter F6
IV
at 558kHz to maximum. Repeat the adjustment
III
reciprocally C3 and L1, end with 1449kHz.
UMS 1 / UMS 2
at 1449kHz and L1
VII
GRUNDIG Service