The display shows CODE 15
The status indicator on the
controller card repeatedly
flashes 15 times
The display shows CODE
16.
The status indicator on the
controller card repeatedly
flashes 16 times
The display shows CODE 17
The status indicator on the
controller card repeatedly
flashes 17 times
Check the cable
1. Switch the spray gun OFF and unplug the power cable from the
connections abo-
device.
ve the motor.
2. Remove motor shroud.
3. Disconnect the motor cable connection and check the connector
for damage.
4. Reconnect the motor controller.
5. Switch on If the error code is still shown, replace the motor.
Check the cable
1. Switch off the power (set to OFF).
connections. The
2. Disconnect the motor position sensor and check the connector
controller is not
for damage.
receiving a motor
position sensor
signal.
3. Reconnect sensor.
4. Switch on the power (set to ON). If the error code is still shown,
replace the motor.
Check the power
1. Switch the spray gun OFF and unplug the power cable from the
supply to the
spraying device.
spraying device
2. Locate a power supply that is working properly to avoid damage
(the spraying
to the electronics.
device is con-
nected to a power
supply with an
incorrect voltage
rating).
175