Fault
The spray gun will not start
up
Display is blank
The status indicator on the
controller car is unlit
The display shows CODE
02
The status indicator on the
controller card repeatedly
flashes twice
The display shows CODE
03
The status indicator on the
controller card repeatedly
flashes three times
Original instruction
Cause
Activity
Check the power
See the section after this table
supply and the
on/off switch
Check the sensor
1. Make sure there is no pressure in the system (see Pressure Relief
or sensor connec-
Procedure). Check the material path for clogging, e.g., clogged fil-
tions.
ter.
2. Use at least an Airless hose ¼" x 15 m. Thinner or shorter hoses
can cause pressure fluctuations.
3. Switch the spray gun OFF and unplug the power cable from the
device.
4. Check the sensor and cable connections on the controller card.
5. Disconnect the sensor from the socket on the controller card.
Make sure that the contacts on the sensor and controller card are
clean and undamaged.
6. Reconnect the sensor with the socket on the controller card.
Switch on the power; set the spray gun to ON, and turn the pres-
sure regulator knob clockwise half a turn. If the spray gun still does
not work properly, switch the device OFF and proceed with the next
step.
7. Install a new sensor. Connect the power cable; switch the the
spray gun ON, and turn the pressure regulator knob clockwise half a
turn. Replace the controller card if the spray gun still does not work
properly.
Check the sen-
1. Switch the spray gun OFF and unplug the power cable from the
sor or sensor
device.
connections (the
2. Check the sensor and cable connections on the controller card.
pressure signal is
3. Disconnect the sensor from the socket on the controller card.
not reaching the
Make sure that the contacts on the sensor and controller card are
controller card).
clean and undamaged.
4. Reconnect the sensor with the socket on the controller card.
Reconnect the power cable; switch the spray gun ON, and turn the
pressure regulator knob clockwise half a turn. If the spray gun still
does not start up, switch the device OFF and proceed with the next
step.
5. Connect a sensor that is working properly to the socket on the
controller card.
6. Switch the spray gun ON, and turn the pressure regulator knob
clockwise half a turn. If the spray gun works, install a new pressure
sensor. Replace the controller card if the spray gun still does not
start up.
7. Check the sensor resistance with an ohmmeter (less than 9000
ohms between the red and black cables, and 3-6 kilo-ohms bet-
ween the green and yellow).