Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring According To Emc Requirements - Lenze 8200 motec Montageanleitung

Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3
motec with motor or geared motor

Wiring according to EMC requirements

Conditions for trouble−free operation:
Except for the mains cable, use shielded cables only.
l
The shield must be carefully connected to PE.
l
Connect motor and mains PE conductors to separate PE terminals.
l
A
B
C
0
Mains cable L1, L2, L3, PE
1
PE connection − mains cable
2
Shielded control cable
3
Shield connection for control cable (screw shield to shield sheet)
4
Function module
5
Isolated terminal (e. g. star point for motor star connection)
X1
Terminal strip − mains connection
PES
HF shield connection by connecting the shield with a surface as large as possible to PE
84
X1
D
EDK82MV222 DE/EN/FR 8.0
Shield connection
1. Prepare cable
2. Route the cable
F
E
3. Tighten the screw.
8200mot101
through the eyebolt
of the shield and
bend the eyebolt.
The shield must be
tightly connected to
the shield sheet.
0.7 Nm
6 lb-in
PES
L

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis