Herunterladen Diese Seite drucken

General Remarks; Safety; Utilisation In Accordance With „Intended Purpose; Symbols Used - Fronius Acctiva Professional Flash Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Acctiva Professional Flash:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

General remarks

Safety

The charger is fitted with the following protection devices for safe handling:
-
-
-
The charger is intended exclusively for charging the following types of battery:
Utilisation in
accordance with
„intended purpo-
„Wet" battery type:
se"
Batteries with liquid (Pb, Ca, Ca silver) or fixed (AGM, GEL, MF, sealant) electrolyte,
used in starter or traction applications.
„Gel" battery type:
Batteries with liquid (Pb, Ca, Ca silver) or fixed (AGM, GEL, MF, sealant) electrolyte,
used in standby applications (e.g. emergency power systems) or at temperatures above
35°C.
Important! Do not charge dry batteries, primary cells or non-rechargeable batteries with
this charger.

Symbols used

WARNING! Risk of injury and damage from exposed, rotating vehicle parts.
When working in the vehicle's engine compartment, take care that hands, hair,
items of clothing and charger leads do not come into contact with moving parts,
e.g. fan belt, fan, etc.
CAUTION! Setting the mode incorrectly can result in product damage and poor
charging performance. Always set the mode according to the type of battery to
be charged.
No sparks when clamping onto battery due to de-energised charging terminals
Protection against short-circuiting of charging terminals/polarity reversal
Protection against thermal overload of the charger
NOTE! No protection from polarity reversal in the case of a deep-discharge
battery. If the battery voltage is too low (< 1.0 V), the charger cannot detect
whether the battery is connected or not. Before starting charging manually,
check that the charging terminals are connected to the correct poles.
Devices equipped with main switch:
-
Switch off main device switch
-
Unplug device from the mains
Devices with no main switch:
-
Unplug device from the mains
Devices equipped with main switch:
-
Connect device to the mains
-
Switch on device main switch
Devices with no main switch:
-
Connect device to the mains