8. Initial operation

Remote control

The water heater's temperature must be limited to 55 °C, if it is connected to a shower
and controlled with a remote control system. The setup menu parameter "Temperature
Limit" ("tL") must be set to a value less or equal 55 °C, in consultation with the cus-
tomer and the lock level must be activated.
When the device is operated with preheated water, it must be ensured that this tem-
perature is limited to 55 °C as well.

Lock level

The operating mode of the appliance can be restricted.
Activation of the lock level
1. Select required level of Lock level via the setup menu (see chapter "How to use,
Setup menu")
2. Disconnect the appliance from the power supply (e.g. by switching off the fuses)
3. Insert the jumper on the power electronics (see picture)
4. Put the appliance into operation again
Deactivation of the lock level
1. Disconnect the appliance from the power supply (e.g. by switching off the fuses)
2. Remove jumper
3. Put the appliance into operation again

Notes in case of remote control connection problems

In case of a failing connection between the remote control and the water heater, the
display indicates "no" and a cyclical flashing radio symbol. A keystroke restarts the
registration.
Under those circumstances reduce the distance to the water heater and check whether
the power supply is turned on.
1. Explain the user how the instan ta neous water heater works and hand over the
operating instructions for the user.
2. Fill in the guarantee registration card and send it to the CLAGE Central Cus to mer
Service or use the online regis tration on our website.

Reinstallation

In case the appliance will be commis sioned again under different installation condi-
tions than during its initial ope ration, it may be necessary to adapt the maximum
power rating.
A temporary short-circuit of the two pins, e.g. with a screwdriver acc. to EN 60900 (see
figure), will reset all heater parameters to works setting and lock the heating. Value
"21" flashes in the display until the maximum power rating has been selected. This
condition will maintain when activating and deactivating the supply voltage.