Herunterladen Inhalt Inhalt Diese Seite drucken

KEB COMBIVERT S4 Betriebsanleitung Seite 59

Vorschau ausblenden Andere Handbücher für COMBIVERT S4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Status Display
Operating State ready:
noP
0
No Operation
LS
70
Low Speed
Operating State run :
Facc
64
Forward Acceleration
Fcon
66
Forward Constant
FdEc
65
Forward Deceleration
rAcc
67
Reverse Acceleration
rCon
69
Reverse Constant
rdEc
68
Reverse Deceleration
rFP
79
ready for positioning
P A
80
positioning active
SrA
82
search for reference active
Operating State Abnormal Condition:
A.OH2 97
abnormal stopping OH
A.dOH 96
abnormal stopping drive OH Quick stop after motor overheating
A.EF
90
abnormal stopping EF
A.PrF/ 94
abnormal stopping prohibited Quick stop caused by one of the
A.Prr
95
rotation forward / reverse
A.bus 93
abnormal stopping bus
Operating State Fatal Error:
E.OC
4
error overcurrent
E.OP
1
error overpotential
E.UP
2
error underpotential
E.OH
8
error overheat
E.dOH 9
error drive overheat
E.OH2 30
error motor protection
E.OL
16
error overload inverter
E.EF
31
error extern fault
E.PrF/ 46
error prohibited rotation
E.Prr
47
forward/reverse
E.OS
105 error overspeed
E.LSF 15
current limit resistor error
E.SEt 39
error at set selection
E.bus 18
error bus
E.EnC 32
error encoder
E.PuC 49
error power unit
E.dSP 51
error DSP
E.hyb 52
error hybrid
E.SLF 110 error software limit forward
E.SLr 111 error software limit reverse
A detailed error description is shown at page GB 43.
The status display indicates the current operating condition of the servo
controller. Possible indications and their meaning are listed in the following:
Control release not briged, modulation switched off,
output voltage = 0, drive uncontrolled
Control release briged, no rotational direction command,
modulation switched off,
output voltage = 0 drive uncontrolled
Drive accelerates forward
Drive runs with constant speed forward
Drive decelerates forward
Drive accelerates in reverse
Drive runs with constant speed in reverse
Drive decelerates in reverse
Drive waits for the positioning to start
Drive executes a positioning command
Drive in reference point search
Quick stop after OH-prewarning
Quick stop after external error
software limit switches
Quick stop after the time monitoring starts for serial
communication (Watchdog)
Overcurrent
Overvoltage
Undervoltage
Overheat in the inverter
Motor overheated
Motor overloaded
Overload KEB COMBIVERT S4
External Fault
Quick stop caused by one of the
software limit switches
Error overspeed
Loading shunt error
Set selection error set x
Time monitoring for serial communication
Error in the resolver interfacing
Error in the power part detection
Internal processor error
Internal hardware error in the hybrid detection
Software limit switch F
Software limit switch R
Parameter Description
GB
GB 25

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis