8.4
Commissioning
WARNING
Risk from electrical voltage!
›
Electrical connection only by trained and instructed qualifi ed personnel!
8.4.1
Check air gap
AW-EX/AXC-EX/AXCBF-EX: Check the minimum air gap between blade tip and housing once again (see Table 11).
DVEX: Check the distance between rotor and nozzle, it must be between 4 mm and 8 mm.
Only put the fan into operation if the minimum air gap matches your fan's value.
8.4.2
Check direction of rotation
WARNING
Risk from bursting parts
›
Wear goggles when checking the direction of rotation of the rotor.
Briefl y switch the fan on and off.
Check the direction of rotation / direction of conveying. The direction of rotation looking at the rotor always
applies.
AW-EX: In fans with intake on both sides, the direction of rotation applies looking at the side opposite the connec-
tion wire.
RVK-EX see Fig. 10
If the direction is wrong, exchange two phases in order to set the direction of rotation.
•
Fig. 10:
RVK-EX fan, throughfl ow direction
8.4.3
Switching on
Switch the fan on.
Check fl awless function (smooth running)
Check tight fi tting of the safety components and protective grid.
62