6.2.2
Assembly
WARNING
Danger from falling parts!
›
Check the underground (ceiling/wall) for strength before assembly,
›
when selecting the fi tting material, pay attention to the weight, vibration tendency and shearing
forces (weight, see name plate).
Fit the fan on a fi rm base with suitable fi tting material at all the fi tting points.
Secure the screw connections with Loctite.
Fit the air channels and the accessories.
6.2.3
AW-EX series: minimum air gap
Size
355
420
550
650
Table 10: Minimum air gap of various construction sizes
When complying with the material combinations, the aforementioned minimum gaps must also be complied with: bet-
ween rotating and stationary parts, the minimum gap may not be smaller than 1 % of the decisive contact diameter,
but no less than 2 mm in an axial or radial direction and may not be more than 20 mm.
NOTE on the condensation opening of the AW-EX series
Pay attention in installation:
-
In installation in a vertical motor shaft position, condensation cannot escape.
-
Installation and operation only admissible in a horizontal shaft position
NOTE for an optimised characteristic
To ensure achievement of the characteristic, it is necessary for a constant and twist-free fl ow to exist at
the inlet. In free intake, this is achieved by the addition of an admission nozzle or a channel line with a
length of no less than 2.5 x D. If this is not possible for construction reasons, a defl ection piece with
baffl es fi tted in front of the fan must be optimised in its fl uidics in such a way that a constant speed
distribution at the fan inlet is achieved.
On the pressure side, a channel or duct element with a length of no less than 2.5 x D is also to be
provided for achievement of the characteristic.
6.2.4
AXC-EX und AXCBF-EX series: minimum air gap
Size
250
315
355/400
450/500
560
630
Table 11:
Minimum air gap of various construction sizes
56
Minimum air gap in mm
3,50
4,20
5,50
6,45
Minimum air gap in mm
2,5
2,5
3,0
3,5
3,5
4,5
Size
Minimum air gap in mm
710
800
900/1000
1250
1400/1600
5,0
5,0
7,0
8,0