The "MOBY D/E/F/I/U" Programs
4.5.7

MOBY U Setup

S Memory size:
S Standby time:
S Working range
1
limitation:
4.5.8

SLG Status

Only MOBY U: The SLG Status function can be used to read version states and
settings of the MOBY U antenna.
The information can be accessed with the "Enter" key in 3 consecutive screens.
S Screen 1:
Hardware, firmware and loader version
S Screen 2:
Driver model, driver version and interface parameters
S Screen 3:
Set working range limitation, standby time and multitagging
(equals 1)
1 Starting with firmware version 2.3.1, the adjustment range is between 0.2 m and 3.5 m. The
distance range limitation can be set in steps of 0.1 m.
E-34
Specify memory size of the MDS to be processed. This
setting can also be used to specify the memory area in
the editor. MDS memory addresses beyond the memory
size cannot be accessed.
The standby time can be set in increments of 7 msec
from 0 msec to 1400 msec. The default value (OFF)
usually does not have to be changed.
The field length (limit distance) is 3 m. It can be set in
increments of 0.5 m to avoid excess working ranges for
the antenna.
The setting range is between 0.5 m and 3.5 m. The
default value is 1 m.
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418
R 06.07