Error Messages
Error Designation Possible Causes and Their Correction
65
66
67
70
80
81, 82
101 to 132
Specification of certain errors:
101
103
104
105
106
107
109
110
E-64
Interface error. Appears when a SIM is connected.
S Check parameters in the "Extras/COMMUNICATION"
menu.
S Check plug and cable to SIM.
General read/write error on MOBY read head
Internal program error on MOBY read head
S Write not successful
S Several tags in the field
MDS type on reader device is not supported.
S Read device sends wrong answer.
S MDS not personalized with MOBY key
S Internal program error (MDS Fxxx)
Read device sent error (MOBY I/U).
Presence error
S No MDS in the field which has the MDS ID number con-
tained in the command.
Error in the connection to the SLG
S Read head hardware has a defect.
Error in MDS memory
S Execute INIT command. Before executing this command,
make sure that the memory size of the MDS is set correctly
under "Extras/MOBY I Setup."
S The MDS is defective.
MOBY command cannot be interpreted by the read head/
MOBY U antenna.
S Check the memory size under "Extras/MOBY I Setup" or
"Extras/MOBY U Setup."
S Field interference on read head. External interference.
S The MDS left the field during communication.
S Field interference during communication
Too many sending errors. The MDS wasn't able to correctly
receive the data from the read head.
S The MDS is located in the boundary area of the read head.
CRC error due to field interference while initializing the MDS
MDS cannot be initialized and is defective.
STG Hand-Held Terminal