General
The following functions can be executed.
S Read data from the MDS
S Write data to the MDS
S Delete the entire data memory (write with a filler value)
S Read and display the ID number of the MDS (MOBY D/E/F/U)
S Read MDS status (MOBY U)
S Read data from OTP memory (MOBY U)
S Write data to OTP memory (MOBY U)
S Represent and edit the data in hexadecimal and ASCII format
S Enable/disable password protection for all write-access functions and for
exiting the MOBY program
S Menu prompting in various languages (currently German and English)
S Store read MOBY data in files. Approximately 1.8 MB are available for this
on the hand-held terminal.
Additional functions with the MOBY I filehandler
S Format the MDS
S Create files on the MDS
S Write files to the MDS
S Read files from the MDS
S Read and display the directory
S Delete files from the MDS
The read/write head of MOBY D/E/F/I is screwed to the PSION basic device.
The head is equipped with a serial TTL interface for communication with the
basic device. The read head is powered by the basic device.
The antenna of MOBY U and the PSION basic device are connected with a
slide catch. Communication takes place via the RS 232 interface. The power
supply of the antenna is provided by an integrated battery pack.
The read/write head or the antenna and the STG program can also be ordered
separately so that customers can continue to use an already existing PSION
Workabout or order a Workabout with a different interface and keyboard config-
uration directly from PSION.
E-2
STG Hand-Held Terminal
(5)J31069-D0126-U001-A5.2-7418