LA 9S-TU(R) - LA 12S-TU(R)
5
Dimensions, weight and filling quantities
5.1
Device dimensions without connections
5.2
Device connections for heating
5.3
Weight of the transportable unit(s) incl. packaging
5.4
Refrigerant / total filling weight
5.5
Lubricant / total filling quantity
5.6
Volume of heating water in device
6
Electrical connection
6.1
Supply voltage / fusing / RCD type
6.2
Control voltage / fusing by WPM
6.3
Degree of protection according to EN 60529
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current with soft starter
6.7
Nominal power consumption A2 W35/ max. power consumption
Nominal current A2 /W35 / cos
6.8
6.9
Power consumption of compressor protection (per compressor)W
6.10 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Frost protection, condensate tray /
Water in device protected against freezing
8.3
Maximum operating pressure (heat sink)
2
9
Heat output COP
9.1
Heat output / COP
10
Cooling capacity / COP
10.1 Cooling capacity / COP
1. For air temperatures between -22°C and -5°C, flow temperature increasing from 45? to 60?.
2. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, other parameters, in particular
the defrosting capacity and regulation, should also be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning
and operation can be found in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: outside air tem-
perature 7 °C and heating water flow temperature 35 °C.
3. The heat output and COP is reduced by approx. 5 % in lower operation
4. When the optional weather protection hood (accessory) is used, the sound pressure level in outlet direction is reduced by 3 dB(A).
5. The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation.
8. The coefficient of performance (COP) in partial load operation can be increased by selecting "energy-optimised heating operation" (natural defrosting)
9. The maximum sound power level under full load can increase by up to 5 dB(A).
EN-12
H x W x L mm
inches
kg
type/kg
type/litres
Litres
A
2
A / ---
W
7
bar
Performance level
at A-7 / W35
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W45
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
2 9
Performance level
at A27 / W18
kW / ---
at A7 / W7
kW / ---
at A35 / W18
kW / ---
at A35 / W7
kW / ---
452168.66.01 · FD 9503
1650 x 910 x 750
G 1 1/4" external thread
225
R410A / 3.9
Polyolester (POE)/1.2
2.6
3~/N/PE 400 V (50 Hz) / C10 A / A
1~/N/PE 230 V (50 Hz) / 4 AT
IP 24
Soft starter
Yes
21
1,7 / 3,3
kW
3,1 / 0,8
70 / thermostatically controlled
< 150
6
Reverse circulation
Yes
3.0
EN 14511
1
5,5 / 3,2
7,2 / 4,2
8,4 / 4,8
8,0 / 3,6
7,7 / 2,9
8,8 / 5,1
EN 14511
1
7,9 / 4,3
5,4 / 3,0
7,0 / 3,2
4,9 / 2,3
1650 x 910 x 750
G 1 1/4" external thread
265
R410A / 4.79
Polyolester (POE)/1.2
3.8
3~/N/PE 400 V (50 Hz) / C10 A / A
1~/N/PE 230 V (50 Hz) / 4 AT
IP 24
Soft starter
Yes
19
2,38 / 4,0
4,3 / 0,8
70 / thermostatically controlled
< 200
6
Reverse circulation
Yes
3.0
EN 14511
2
1
---
7,3 / 3,1
8
---
9,5 / 4.0 (4,2)
---
11,3 / 4,7
---
10,8 / 3,8
---
10,0 / 3,0
---
12,0 / 5,0
EN 14511
2
1
---
8,6 / 3,6
---
6,3 / 2,6
---
7,9 / 2,8
---
5,3 / 2,0
www.dimplex.de
2
---
---
---
---
---
---
2
---
---
---
---