Herunterladen Inhalt Inhalt Diese Seite drucken

Transmitter Signal Input; Signal Inputs/Outputs On Receiver - Siemens SIMATIC FS400 Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

12.1.3 Transmitter signal input

Terminal 4: Test input
Table 12.1-3: Transmitter, signal input
PG 13.5
Terminal 4
Table 12.1-4: Terminal 4 on PG 13.5 transmitter end cap to Hirschmann, MIN-style

12.1.4 Signal inputs/outputs on receiver

Terminal 5: EDM (contactor
monitoring) *
Terminal 6:
Start/restart button *
Collective malfunction/dirt signal
Table 12.1-5: Receiver, machine interface, status and control signals
* The "restart interlock" and "dynamic contactor monitoring" functions are only available
in the extended mode
PG 13.5
Terminal 5
Terminal 6
Table 12.1-6: Terminal 5 and terminal 6 on PG 13.5 receiver end cap to Hirschmann,
194
Input:
Hirschmann plug
PIN 4
and M12 transmitter end caps.
Input:
Input:
Output:
Hirschmann plug
PIN 5
PIN 6
MIN-style and M12 receiver end caps.
Closed current principle, minimum
open time, 50ms
MIN-style plug
M12 plug
(5-pin)
PIN 4
PIN 4
Contacts (break) against 24 V DC
current load: max. 20 mA
Contact (make) against 24 V DC
current load: max. 15 mA
pnp: Typical 22 V DC switching, max.
80 mA
MIN-style plug
M12 plug
(7-pin)
PIN 5
PIN 3
PIN 6
PIN 1

Quicklinks ausblenden: