12.1.2 General system data

Safety type in accordance with
EN IEC 61496
Synchronization
Supply voltage
Residual ripple of supply
voltage
Shared value for external fuse
in the supply line for transmitter
and receiver
Safety class (VDE 106)
Type of protection
Temperature range, operation
Temperature range, storage
Relative humidity
Vibration fatigue limit
Resistance to shocks
Profile cross-section
Dimensions
Weight
Transmitter
Light-emitting diodes:
Class in accordance with EN
60825-1:1994+
A1:2002+A2001
Wavelength
Power
Power consumption
*)
Without additional measures the devices are not suited for outdoor use.
Table 12.1-2: General system data
192
Type 4
Optical via transmitter and receiver
± 20 %, external power supply with secure
24 V
DC,
mains supply isolation and equalization of voltage
failures up to 20 ms required, at least 380mA
(plus OSSD load)
± 5% within the limits of U
2 A melting fuse
III
IP 65*
0 ... +55 °C
-25 ... +70 °C
15 ... 95%
5 g, 10 - 55 Hz according to IEC/EN 60068-2-6
10 g, 16 ms according to IEC/EN 60068-2-29
See dimensional drawings and tables in
Chapter 12.2
See table in Chapter 12.2
1
880 nm
< 50 µW
75 mA (with 24 V DC supply voltage)
(100mA AS-i)
v