12

Technical data

12.1

General data

12.1.1 Beam/protective field data

Resolution
14 mm
30 mm
50 mm
90 mm
Beam
distance
in mm
500 mm
500 mm
500 mm
400 mm
400 mm
400 mm
300 mm
300 mm
Beam
distance
in mm
500 mm
600 mm
Table 12.1-1: Beam/protective field data
Range
min.
max.
0 m
6 m
0 m
18 m
0 m
18 m
0 m
18 m
Number
Range
of
min.
beams
2
0 m
2
6 m
2
6 m
3
0 m
3
6 m
3
6 m
4
0 m
4
6 m
Number
Range
of
min.
beams
2
0 m
(1 beam
folded)
2
0 m
(1 beam
folded)
Protective field height
min.
150 mm
150 mm
450 mm
750 mm
Heights of beams above
reference level in mm (EN 999)
max.
18 m
400, 900
70 m
400, 900
70 m
400, 900
18 m
300, 700, 1100
70 m
300, 700, 1100
70 m
300, 700, 1100
18 m
300, 600, 900, 1200
70 m
300, 600, 900, 1200
Heights of beams above
reference level in mm (EN 999)
max.
6.5 m
400, 900
6.5 m
300, 900 (ANSI - USA)
max.
1,800 mm
1,800 mm
3,000 mm
3,000 mm