Oil, Fig. 5
Warning: For the first use, the compressor must be filled with
oil
Operating the machine without oil will cause irreparable
damage and render the warranty invalid.
1 Remove the plastic oil inlet plug (14) on top of the
crank box of the compressor casing.
2 Fill the oil supplied into the crank box until the oil
level in the sight glass (16) reaches the centre of the
red circle.
3 Re-attach the oil inlet plug (14) and tighten it firmly.
Air filter, Fig. 6
Warning: The air filter must be fitted before the first use.
An operation without filter damages the compressor and
renders the warranty invalid.
The air-filter on the (15) is screwed tight on the right side
of the cylinder
Putting into operation
Warning:
Fill in oil before starting the compressor for the first time.
1 Make sure the place of setting up is clean, dry, and
well vented.
2 Make sure the crank box is filled with oil, and the air
filter is fitted.
3 Start the compressor as described in the chapter
„Switching on and off the compressor". At switching
on for the first time, let the compressor run for ten
minutes at no load with the drain valve open, so that
all the parts get well lubricated.
Warning: As compressed air comes off the output, the out-
put may not be directed towards the operator or people
in the vicinity. The air coming off the exit may not be in-
haled. Daily check the pressure control valve.
Switching on and off the compressor, Fig. 7
1 Check the model plate on the compressor: 230 – 240
V (or 110 – 120 V).
2 Plug the compressor cable into a standard socket (240
V or 120 V) and switch the compressor on.
3 For switching the compressor on, lift the ON/OFF switch
(3) on the pressure switch cover (2).
4 For switching the compressor off, depress the ON/OFF
switch.