Herunterladen Inhalt Inhalt Diese Seite drucken

Hitachi WH 14DCAL Bedienungsanleitung Seite 10

Akku-winkelschlagschrauber
Vorschau ausblenden Andere Handbücher für WH 14DCAL:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 14
English
CHARGING
〈 UC18YRL 〉
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to a receptacle
When the power cord is connected, the charger's
pilot lamp will blink in red (At 1-second intervals).
2. Insert the battery into the charger
Insert the battery firmly, until it contacts the bottom of
the charger compartment. (See Fig. 3)
CAUTION
If the battery is inserted in the reverse direction, not
only recharging will become impossible, but it may
also cause problems in the charger such as deformed
recharging terminal.
Table 1
Before
Blinks
charging
(RED)
Lights
While
(RED)
charging
Blinks
Charging
(RED)
complete
Charging
Flickers
impossible
(RED)
Overheat
Lights
standby
(GREEN)
NOTE: When standby for cooling battery, UC18YRL cools the overheated battery by cooling fan.
(2) Regarding the temperatures of the rechargeable battery
The temperatures for rechargeable batteries are as
shown in Table 2, and batteries that have become hot
should be cooled for a while before being recharged.
Table 2 Recharging ranges of batteries
Charger
Rechargeable batteries
Ni-Cd batteries
Ni-MH batteries
Li-ion batteries
(3) Regarding recharging time
Depending on the combination of the charger and
batteries, the charging time will become as shown in
Table 3.
Table 3 Charging time (At 20°C)
Charger
Battery
EB14B
Approx. 30 min. Approx. 50 min.
BCL1430
Approx. 45 min.
9
Indications of the lamps
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights continuously
Lights for 0.5 seconds. Does not light for
0.5 seconds. (off for 0.5 seconds)
Lights for 0.1 seconds. Does not light for
0.1 seconds. (off for 0.1 seconds)
Lights continuously
UC18YRL
UC18YG
–5°C – 55°C
0°C – 45°C
–5°C – 50°C
0°C – 50°C
UC18YRL
UC18YG
3. Charging
When inserting a battery in the charger, charging will
commence and the pilot lamp will light up
continuously in red.
When the battery becomes fully recharged, the pilot
lamp will blink in red (At 1-second intervals) (See
Table 1).
(1) Pilot lamp indication
The indications of the pilot lamp will be as shown in
Table 1, according to the condition of the charger or
the rechargeable battery.
NOTE
The charging time may vary according to temperature
and power source voltage.
4. Disconnect the charger's power cord from the
receptacle
5. Hold the charger firmly and pull out the battery
NOTE
Be sure to pull out the battery from the charger after
use, and then keep it.
CAUTION
If the battery is charged while it is heated because it
has been left for a long time in a location subject to
direct sunlight or because the battery has just been
used, the pilot lamp of the charger lights up green. In
such a case, first let the battery cool, then start charging.
When the pilot lamp flickers in red quickly (at 0.2-
second intervals), check for and take out any foreign
objects in the charger's battery installation hole. If
there are no foreign objects, it is probable that the
battery or charger is malfunctioning. Take it to your
Authorized Service Center.
Since the built-in micro computer takes about 3
seconds to confirm that the battery being charged
with UC18YRL is taken out, wait for a minimum of 3
seconds before reinserting it to continue charging. If
the battery is reinserted within 3 seconds, the battery
may not be properly charged.
Malfunction in the battery
or the charger.
Battery overheated.
Unable to charge
(Charging will commence
when battery cools).

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Wh 14dy

Inhaltsverzeichnis