  • DEUTSCH, seite 1
– The appliance must only be transported
by properly trained crane personnel.
– Do stand stand below the load.
– Ensure that no persons are present in
the immediate vicinity of the crane.
– Do not leave the appliance on the crane
unattended.

Shutdown

Warning
Risk of damage! Freezing water in the ap-
pliance can destroy parts of the appliance.
For longer work breaks or if a frost free stor-
age is not possible:
Drain water.
Flush device with anti-freeze agent.
Drain water
Screw off water supply hose and high
pressure hose.
Operate device for max. 1 minute until
the pump and conduits are empty.
Flush device with anti-freeze agent
Note
Observe handling instructions of the anti-
freeze agent manufacturer.
Pump in conventional frost protection
agents through the appliance.
A certain corrosion protection is achieved
with this as well.

Maintenance and care

Risk of injury
Always switch off the appliance and pull out
the mains plug before care and mainte-
nance work.
Safety inspection/ maintenance
contract
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract.
Please take advice on this matter.

Maintenance intervals

Daily
Check oil level of the high pressure
pump.
The oil level must be between the "MIN"
and "MAX" markings on the oil contain-
er.
Add oil if required (see technical speci-
fications).
Warning
In case of lacteous oil inform Kärcher cus-
tomer service immediately
Weekly or after 40 operating hours
Clean filter at the water connection.
Clean filter at the detergent suck hose.
Check the swimmer valve in the swim-
mer container for leaks.
After 50 operating hours
Change the oil in the high pressure
pump.
monthly or after 500 operating hours
Change the oil in the high pressure
pump.
Maintenance Works
Clean filter at the water connection
Unscrew the filter casing, remove the
filter, clean it and replace it.
Clean filter at the detergent suck hose
Take out detergent suck hose.
Clean filter in water and reinstall.
Oil change.
For oil type refer to technical specifica-
tions.
Turn out the oil drain screw.
Drain the oil in a collection basin.
Screw in oil drain plug.
Slowly fill in new oil until the "MAX"
marking on the oil container.
Note
Air pockets must be able to leak out.
19