Max. cell voltage when charging
The maximum cell voltage can be set depending on the set rechargeable
battery type (LiPo, LiIon, LiFe, LiHv and Pb).
The charger ends charging when all cells have reached the set voltage.
LiPo:
4.00 - 4.24 V/cell (basic setting 4.20 V)
LiIon:
3.90 - 4.20 V/cell (basic setting 4.10 V)
LiFe:
3.40 - 3.65 V/cell (basic setting 3.60 V)
LiHv:
4.00 - 4.40 V/cell (basic setting 4.30 V)
Pb:
2.20 - 2.40 V/cell (basic setting 2.40 V)
Loading factory settings (reset)
This recovers the factory settings (reset).
Keep the button "START/ENTER" pressed for more than 2 seconds.
Then the charger starts again and will then be in the main menu again.
Observe that all values set by you are then reset to factory settings; the 10 rechargeable battery memories
(see chapter 14) are also deleted.
Battery end volt
LiPo
4.20V/C
Battery end volt
LiIo
4.10V/C
Battery end volt
LiFe
3.60V/C
Battery end volt
LiHv
4.30V/C
Battery end volt
Pb
2.40V/P
Factory reset
Press Enter > 2S