Error
State
F71
Door neither opens nor
closes. Erroneous wicket
door contact.
F72
Door neither opens nor
closes
F73
Door neither opens nor
closes. Testing of in-
put J4.1/2 failed
F74
Door neither opens nor
closes. Testing of in-
put J4.3/4 failed
F75
Door neither opens nor
closes. Output voltage J4
erroneous
F76
Door neither opens nor
closes. Invalid sensors
J4.1/2 detected
F77
Door neither opens nor
closes. Invalid sensors
J4.3/4 detected
F78
Drive blocks in end posi-
tion CLOSE
If the safety circuit is inter-
rupted, the warning indic-
ator is illuminated, see
troubleshooting.
Other frequency converter-specific error displays
Error
State
F56
Door neither opens nor
closes
F57
Door neither opens nor
closes
F60
Door neither opens nor
closes
Diagnosed cause
Check contact resistances.
Check assembly of the
wicket door contact. Open
and close wicket door,
check assembly.
Short circuit detected in the
safety circuit wicket door
contact / slack rope switch
J4.1/2. Check cables for
short circuit, eliminate short
circuit.
Switch control on and off. If
necessary, replace control.
Switch control on and off. If
necessary, replace control.
Switch control on and off.
Check closing edge safety
device, door connection box
for short circuit. Check ter-
minal assignment.
Check resistors. Check
sensors.
Check resistors. Check
sensors.
Check spring tension, check
door mechanics, check
CLOSE end position.
Diagnosed cause
Overcurrent on IGBT
module
Overtemperature frequency
converter
Motor connection interrupted
T100 R-FU 3 kW
9

Maintenance

Tasks to be performed before starting maintenance
Hazardous voltage!
DANGER
Fatal electric shock when touching live parts. Ob-
serve the following safety rules when working on
the electrical system:
Disconnect from the mains.
Secure against inadvertent switch-on.
Verify de-energised state.
Work on the electrical system may only be
performed by skilled electricians or instruc-
ted persons working under the direction and
supervision of a skilled electrician in accord-
ance with the electrotechnical rules and dir-
ectives.
NOTICE
NOTICE
For your safety, we recommend that the door
system be checked before initial use and as
needed – at least once a year – in accordance
with the check list in the Inspection chapter. The
check can be carried out by a person with the
corresponding qualification certificate or by a
specialist company.
10

Disassembly

Disassembly is carried out in reverse order of the assembly in-
structions in the Installation chapter.
11

Disposal

Dispose of packaging material in an environmentally friendly way
and in accordance with the applicable local disposal regulations.
The symbol with the crossed-out waste bin on waste elec-
trical or electronic equipment stipulates that this equipment must
not be disposed of with the household waste at the end of its life.
The separate collection of waste electrical and electronic equip-
ment aims to enable the re-use, recycling and other forms of re-
covery of waste equipment as well as to prevent negative effects
for the environment and human health caused by the disposal of
hazardous substances potentially contained in the equipment.
Dispose of the waste electrical or electronic equipment in accord-
ance with national legislation.
UK (The following applies for the United Kingdom)
According to Waste Electrical and Electronic Equipment Regula-
tions 2013 (SI  2013/3113) (as amended) devices that are no
longer usable must be collected separately and disposed of in an
environmentally friendly manner.