4
Installation
Hazardous voltage
DANGER
The product works with low voltage
(230/400 V AC). Before starting with the installa-
tion,observe the following:
•
Have all work on electrical connections car-
ried out by a skilled electrician.
•
The power connection must be executed in
compliance with the mains voltage avail-
able.
Follow the instructions as well as the illustrations in the
"Connection diagrams" chapter.
1.
Tools required
For the assembly of the control, you require the following tools:
•
wooden folding rule or tape measure
•
cross-tip screwdriver Phillips; size 2
•
drilling machine
•
drill 6 mm
•
Torx screwdriver, size T20
•
slotted screwdriver for electricians
•
spirit level
•
Allen key size 3
•
marking pencil
2.
Opening the cabinet door
Hazardous voltage
DANGER
The product runs on high voltage Before opening
the frequency converter cover, observe the fol-
lowing:
•
Disconnect all poles of the mains voltage.
•
Allow residual voltage to dissipate for
1 minute.
•
Secure against unauthorised switch-on.
•
Operation without the frequency converter
cover is not permitted.
Open the cabinet door by unlocking the two locks with the corres-
ponding double bit key. Then remove the frequency converter
cover by loosening the four screws on the frequency converter
cover with a size 3 Allen key.
3.
Assembly of the control
Assemble the control as specified on the drilling drawing.
Selection of the place of installation
NOTICE
When selecting the place of installation, observe
the preconditions in compliance with the tech-
nical data.
24 - EN
4.
Terminal designation
J1
Start / pulse input (OPEN / STOP / CLOSE
J2
Photoelectric safety barrier 2- or 4-wire
J3
Safety edge OSE / 8K2 / DW / light grid
J4
Emergency stop, slack rope, locking
J5
No function
J6
Anti crash detector
J7
Key switch / pull switch
J8
Timer inputs
J9
Digital limit switch
J10
Connection of extended controls
J11
Connection of radio receiver
J12
Antenna
J13
Membrane keypad
J14
Plug-in module (DC, RSE)
J15
Frequency converter (internal wiring)
J16
Service interface
X1
Power connection
X2
Power output L, N (500 W / 230 V)
X3
Protective earth contact
X4a
Magnetic brake
X4b
Release signal frequency converter (internal wiring)
X5
Potential-free relay contact 1, door status relay
X6
Potential-free relay contact 2, door status relay
X7
Frequency converter supply (internal wiring)
X8a
Connection light grid - sender
X8b
24 V DC, max. 700 mA
5.
Mains connection
The control is wired in a ready-to-connect fashion using a 16 A
CEE plug and a cable with an approximate length of 1 m as
shown in the illustration. Connect the control via an all-pole line
disconnecter ≥ 10 A complying with the specifications of
EN 12453 to the house wiring system. In doing this, ensure that
the line disconnecter is easily accessible after the installation.
Checking the mains connection
NOTICE
•
•
•
•
T100 R-FU 3 kW
Ensure that on-site fusing of 16 A is avail-
able.
Check whether the mains connection on
site complies with the pre-wired mains con-
nection of the control.
If the mains connection shows any devi-
ations, the control must be rewired.
For on-site fusing, only use all-current sens-
itive residual current circuit breakers of
type B.