EMERGENCY operation
Risk of being crushed or hit by the moving
WARNING
door in EMERGENCY operation
Persons can be struck when the door is closed
or collide with the door.
•
For EMERGENCY operation the door
needs to be checked and found to be in per-
fect condition.
•
While the "Dead man" operating mode is
active, a clear view to the door from the
place of operation must be ensured.
EMERGENCY operation permits the operation of the door with
defective or tripped safety devices.
EMERGENCY operation is activated after 5 seconds of perman-
ent actuation of "OPEN" or "CLOSE" whilst E06 or E07 is dis-
played and is indicated by an F30 message on the display.
Lighting and / or an advance warning light (optional)
The control is provided with 2 relay outputs by means of which
the lighting or the advance warning light is switched (menu
items 45 and 46).
External control devices / pulse generators (optional)
The door can be opened and closed by external control devices /
pulse generators.
Radio hand-held transmitter (optional)
The operating mode for the radio hand-held transmitter can be
selected in menu 6 – menu item 64.
Start button (functional process in pulse OPEN operating mode /
pulse CLOSE):
•
Initial pulse generation:
Drive starts and moves the door to the end position OPEN
or CLOSE that is set.
•
Pulse generation during the process:
Door stops.
•
New pulse:
Door continues moving in the opposite direction.
AR operation:
•
Pulse generation: Door opens
½ door opening button
•
Function as for the start button, however, the door only
approaches the ½ door opening that is set.
Light button:
•
The light function is a continuous light, which can be
switched irrespective of the "ON / OFF" door action.
Key switch function (optional)
The control is provided with an input for a key switch. This allows
you to activate various functions using menu item 50, "Key switch
function".
Door action status display
Display State
Upper end position OPEN reached
Door end position has not been reached
Lower end position CLOSE reached
Representation of the door opening frequency
Representation of the door closing frequency
Inner segment display flashes: Timer for automatic
closing is active
or
Control is ready to operate
Only in AR operation: continuous start detected at
input terminals J1, J7 or J8
Force learning cycle is carried out (menu item 48).
T100 R-FU 3 kW