Magnetic ring (if supplied and packed with the accessories)
1 2
3
5. . Clamp down cable with the designated cable clamp to secure it in place. The cable should not be loose,
and should not pull on the u-lugs.
6. Reinstall the electric box cover and the front panel of the indoor unit.
Power Specifications
PHASE
POWER
´FREQUENCY AND VOLT
CIRCUIT BREAKER/FUSE (A)
INDOOR UNIT POWER WIRING (mm2)
OUTDOOR UNIT POWER WIRING
INDOOR/OUTDOOR
STRONG ELECTRICAL SIGNAL
CONNECTING
WIRING (mm2)
WEAK ELECTRICAL SIGNAL
GROUND WIRING
NOTE: When taking out the electric control box, pay attention
to loosen and remove the terminal.
Pass the belt through
the hole of the Magnetic ring
to fix it on the cable
CAUTION
•
Illustrations in this manual are for explanatory purposes. The
actual shape shall prevail.
•
While connecting the wires, please strictly follow the wiring
diagram.
•
The refrigerant circuit can become very hot. Keep the
interconnection cable away from the copper tube.
•
1 Phase
220-240V-, 50Hz/60Hz
20/16
--
3x1.5
4x1.0
--
1.5
39
1 Phase
220-240V-, 50Hz/60Hz
20/16
--
3x2.5
4x1.0
--
2.5