Install Your Outdoor Unit
1
Select installation location
: PRIOR TO INSTALLATION
NOTE
Before installing the outdoor unit, you must choose an appropriate location. The following are standards that will
help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
60cm (24")
above
30cm (12")
on left
200cm (79")
in front
Meets all spatial requirements shown in Installation
Space Requirements above.
Install the unit by following local codes and regulations , there may be differ slightly between
NOTE
different regions.
CAUTION:
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the direction of the wind. If needed, build a barrier in front of the unit
to protect it from extremely heavy winds. See Figures below.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air flow around the unit.
If the unit is frequently exposed to salty air(seaside):
Use outdoor unit that is specially designed to resist corrosion.
Strong
wind
90° angle to the
direction of the wind
DO NOT install unit in the following locations:
Near an obstacle that will
block air inlets and
outlets.
Near a public street, crowded
areas, or where noise from
the unit will disturb others.
30cm (12")
from back wall
Good air circulation
and ventiation.
60cm (24") on
right
Protected from prolonged periods
of direct sunlight or rain.
Strong
wind
Build a wind Baffle to
protect the unit
Near animals or plants that
will be harmed
by hot air discharge.
Near any source of
combustible gas.
31
Firm and solid—the
location can support the
unit and will not vibrate.
Long-term
Where snowfall is anticipated, take
appropriate measures to prevent ice
buildup and coil damage.
Wind Baffle
Strong
wind
protect the unit
In a location that is exposed to large
amounts of dust
Noise from the unit will
not disturb other people.
Shelter
Build a shelter to
loading