CLEANING AND MAINTENANCE WARNINGS
Turn off the device and disconnect the power before cleaning. Failure to do so can cause
•
electrical shock.
Do not clean the air conditioner with excessive amounts of water.
•
•
Do not clean the air conditioner with combustible cleaning agents. Combustible cleaning
agents can cause fire or deformation
Note about Fluorinated Gasses
This air-conditioning unit contains fluorinated greenhouse gasses. For specific information
•
on the type of gas and the amount, please refer to the relevant label on the unit itself or the
"Owner's Manual - Product Fiche " in the packaging of the outdoor unit.
Installation, service, maintenance and repair of this unit must be performed by a certified
•
technician.
•
Product uninstallation and recycling must be performed by a certified technician.
When the unit is checked for leaks, proper record-keeping of all checks is strongly
•
recommended.
WARNING FOR USING R32/R290 REFRIGERANT
When flammable refrigerant are employed, appliance shall be stored in a
•
well-ventilated area where the room size corresponds to the room area as specifiec for
•
operation.
For R32 frigerant models:
•
•
Appliance shall be installed, operated and stored in a room with a floor area larger than 18 m2 .
Appliance shall not be installed in an unvertilated space, if that space is smaller than 18 m2
•
(Please see the following form).
Model (Btu/h)
<18000
Reusable mechanical connectors and flared joints are not allowed indoors.
•
(EN Standard Requirements).
•
Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of
•
the maximum allowable pressure. When mechanical connectors are reused indoors, sealing
parts shall be renewed. When flared joints are reused indoors, the flare part shall be re-
fabricated. (UL Standard Requirements)
When mechanical connectors are reused indoors, sealing parts shall be renewed. When
•
flared joints are reused indoors, the flare part shall be re-fabricated.
(IEC Standard Requirements)
•
•
Mechanical connectors used indoors shall comply with ISO 14903.
Minimum room area (m2)
18
22