Herunterladen Diese Seite drucken

ELL Solid RG10A/BGEF Bedienungsanleitung Seite 31

Verfügbare Sprachen

Verfügbare Sprachen

Step 5: Connect drain hose
The drainpipe is used to drain water away from the
unit. Improper installation may cause unit and property
damage.
CAUTION
• Insulate all piping to prevent condensation, which
could lead to water damage.
• If the drainpipe is bent or installed incorrectly, water
may leak and cause a
water-level switch malfunction.
• In HEAT mode, the outdoor unit will discharge water.
Ensure that the drain hose
is placed in an appropriate area to avoid water
damage and slippage.
• DO NOT pull the drainpipe forcefully. This could
disconnect it.
Drain hose
Drainpipe
Pipe clasp
connecting
port
NOTE: When connecting multiple drainpipes, install
the pipes as illustrated.
≥10cm
(4")
In order to ensure smooth drainage, the height hanging
difference between the wall outlet and the
hanging plate must be greater than 470mm.
Recommended opening location of
connecting pipe outlet
Lean over 1/100
In order to ensure smooth drainage, the height When
installing the drainage pipe, hanging plate must be greater
than 470mm.
30
NOTE ON DRAINPIPE
INSTALLATION
• When using an extended drainpipe, tighten the
indoor connection with an additional
protection tube. This prevents it from pulling loose.
• The drainpipe should slope downward at a gradient
of at least 1/100 to prevent water
from flowing back into the air conditioner.
• Incorrect installation could cause water to flow back
into the unit and flood.
55
loading

Verwandte Produkte für ELL Solid RG10A/BGEF

Diese Anleitung auch für:

Solid rg10ab2s/bgef