13. Storing the equipment

Store the device and its accessories in a dark, dry and
frostproof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.

14. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The custom-
er's mains connection as well as the extension ca-
ble used must also comply with these regulations.
Important information
In the event of an overloading the motor will switch it-
self off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been improp-
erly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the
wall outlet
• Cracks due to the insulation ageing
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking "H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
If it is necessary to replace the connection cable, this
must be done by the manufacturer or their representa-
tive to avoid safety hazards.
AC motor:
• The mains voltage must be 220-240 V~.
• Extension cables up to 25 m length must have a
cross section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Motor data - type plate
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.

15. Disposal and recycling

Notes for packaging
Notes on the electrical and electronic equipment
act [ElektroG]
Waste electrical and electronic equipment
does not belong in household waste, but
must be collected and disposed of sepa-
rately!
• Used batteries or rechargeable batteries that are not
installed permanently in the old appliance must be
removed non-destructively before disposal. Their
disposal is regulated by the battery law.
• Owners or users of electrical and electronic devices
are legally obliged to return them after use.
• The end user is responsible for deleting their per-
sonal data from the old device being disposed of!
• The symbol of the crossed-out dustbin means that
waste electrical and electronic equipment must not
be disposed of with household waste.
• Waste electrical and electronic equipment can be
handed in free of charge at the following places:
- Public disposal or collection points (e.g. municipal
works yards)
www.scheppach.com
.
2
The packaging materials are recy-
clable. Please dispose of packag-
ing in an environmentally friendly
manner.
GB | 41
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

59013029015901302903590130299695901302906

Inhaltsverzeichnis