Assembling Instructions for Specialist Staff Only
1

Mounting the power supply

Figure 1
Mount the power supply to the cabin ceiling or wall or
in accordance with manufacturer's recommendations.
A power supply cord with an earthing pin plug (not
included in standard delivery) carries the electricity.
CAUTION - Damages of Device:
Mount the power supply unit at a dry location. With
environmental conditions of 40° Celsius and a ma-
ximum of 95 percent humidity.
1. Carefully remove the cover 2 (with pre- moun-
ted electronic component) of the power supply by
unscrewing the four recessed head screws 4 x 12
mm.
2. Fasten the housing 1 with the four, 25 mm long
wooden screws supplied, to the cabin ceiling or ca-
bin wall.
3. Replace the cover 2 on the housing 1 so that
the connecting plugs are located in the housing
openings.
4. Guide the 10-pin flat stripwiring 4 into the 10-wire
socket 3 on the side of the housing.
CAUTION - Damages of Device:
You are only allowed to use the infrared control unit
for controlling 3 heating circuits with a maximum
heating capacity of 1,2 kW per heating circuit.
5. All of the components are connected to the power
supply 1 according to Figure 1.
The plugs for the connection of the heating ele-
ments and the cabin lighting are not included. The
appropriate plugs (without leads) are available as
accessories (plug system GST 18).
Heating elements:
Cabin lighting:
CAUTION - Damages of Device:
Allow free air circulation for the cooling of the po-
wer supply. The power supply may not be covered
by objects or materials.
12
plug (black)
plug (silicon grey)
2

Mounting the infrared control

Figure 2
Mount the infrared control to the outer cabin wall while
keeping a maximum distance of 3 meters to the power
supply unit.
CAUTION - Damages of Device:
The infrared control is drip-proof (degree of protec-
tion IP 43). Nevertheless, the infrared control may
not come in contact with water.
To attain the degree of protection of IP 43, the infra-
red control has to be recessed in the cabin wall.
Mount the infrared control at a dry location.
1. Cut a 25 mm deep opening with a maximum width
of 100 mm and a maximum height of 156 mm in
the cabin wall.
2. Provide wiring arrangements for the connection
lines.
3. Slightly push in the safety lock with a screwdriver
and remove the upper housing cover 4.
4. Through the bore holes 6 screw the housing with
four wooden screws to the cabin wall.
5. Stick on 10-pin plug 5 of the flat band wiring.
6. Stick on 2-pinplug of the inside temperature sensor.
Applies to heating element systems only:
7. Pull off 2 PIN jumper 1 in the control unit.
Applies to foil heating systems only:
8. Stick on 3-pin plug of the foil temperature sensor 2.
9. Guide the lines of the foil and inside temperatu-
re sensors to the mounting locations.
10. Stick on 2 PIN jumper 1 (connector jumper)
control unit.
NOTE - Configuring the variants:
Plugged jumper 1 = foil heating system
Removed jumper 1 = heating element system