Assembling Instructions for Specialist Staff Only
3
Mounting the inside temperature
sensor - Figure 3
Mount the inside temperature sensor in the sauna ca-
bin, about 30 cm below the ceiling, or in accordance
with manufacturer specifications.
The maximum distance to the infrared control should
not exceed 2 meters.
CAUTION - Destruction of the heating foil:
The heating foil is located directly behind the sauna
wall of all infrared foil heating systems.
Do not mount the inside-temperature sensor direct-
ly above the heating foil.
CAUTION - Wrong measured values:
If the inside temperature sensor has been mounted
too close to the heater, it will indicate wrong measu-
red values. Keep a minimum horizontal distance of
about 30 cm to the heater and about 30 cm to the
cabin ceiling.
Do not mount the inside temperature sensor above
the infrared heating elements.
1. Fasten the inside temperature sensor 1 with two
wooden screws to the cabin wall.
2. Run the 2-pin line 2 in the cabin wall and fasten
with wiring clips.
4
Mounting the foil temperature
sensor - Figure 4
Mount the foil temperature sensor directly to the infra-
red foil heating and fasten with a pull protection.
The maximum distance to the infrared control should
not exceed 2 meters
CAUTION - Wrong measured values:
If the foil temperature sensor has not been mounted
directly to the foil, it will indicate wrong measured
values.
Mount the foil temperature sensor directly to the foil.
NOTE:
The foil temperature sensor is only required in connec-
tion with infrared foil heating systems.
1. Mount the sensor head 5 of the foil temperature
sensor 1 directly between the insulating mate-
rial and the heating foil 4.
2. Fasten the foil temperature sensor 1 with the
pull-relief 2 on the outside of the foil area.
3. Run the 2-pin line 3 in the cabin wall and fasten
with wiring clips.
4. Depending on the model of the heating system
and the cabin, per heating circuit it is necessary
to install an overtemperature fuse and connect it
together to the power unit. To do so, the power unit
has been equipped with a 2-pin plug connector.
If necessary, the mounted jumper may have to be
removed.
You can obtain more information for this from your
cabin manufacturer.
13